412-03-3 412-03-3 Air Conditioning • DTC B2518 Compressor Overtemperature Fault DIAGNOSIS AND TESTING Air Conditioning — The interface adapter assembly (IAA) module uses the A/C overtemperature sensor to Diagnostic Trouble Code (DTC) Definition monitor the temperature of the A/C The following DTCs relate to the air conditioning compressor. The IAA module sets DTC B2606 (A/C) system: if the compressor temperature is greater than ° C (171 ° F) for more than 5 seconds. If this • DTC P1461 A/C Pressure Sensor Circuit High occurs, the A/C compressor will be disabled. Input The compressor will turn back on when the — The interface adapter assembly (IAA) module temperature decreases below 67 ° C (153 ° F). uses the A/C pressure sensor to monitor the • DTC B2606 A/C Temperature Sensor Out of pressure on the high side of the A/C Range compressor. The IAA module sets DTC P1461 — The interface adapter assembly (IAA) module when the ambient temperature is greater than uses the A/C overtemperature sensor to 18 ° C (64 ° F) and the pressure has been less monitor the temperature of the A/C than 80 kPa (12 psi) or greater than 3275 kPa compressor. The IAA module sets DTC B2518 (475 psi) for more than 30 seconds. if the compressor temperature is greater than • DTC B1946 A/C Post Evaporator Sensor Circuit 125 ° C (257 ° F) or less than -40 ° C (-40 ° F) for Failure more than 30 seconds. If this occurs, the A/C — The interface adapter assembly (IAA) module compressor will be disabled. uses the evaporator temperature sensor to Electrical Schematic monitor the temperature of the A/C evaporator Refer to Electrical and Vacuum Troubleshooting evaporator temperature is greater than 55 ° C Manual, Cell 54, Air Conditioner/Heater for (131 ° F) or less than -40 ° C (-40 ° F) for more schematic and connector information. than 30 seconds while the A/C is running. Inspection and Verification • DTC B2119 Compressor Failure Refer to — The interface adapter assembly (IAA) module monitors the A/C compressor speed feedback Symptom Chart Symptom Chart Condition Possible Sources Action • DTC P1461 A/C Pressure • Low refrigerant. Sensor Circuit High Input • Refrigerant leak. • Circuit(s). • Interface adapter assembly (IAA) module. • A/C pressure sensor. • DTC B1946 A/C Post • Evaporator temperature Evaporator Sensor Circuit sensor. Failure • Circuit(s). • Interface adapter assembly (IAA) module. |