Symptom: DRIVER WINDOW DOWN OUTPUT SHORT TO GROUND When Monitored and Set Condition: DRIVER WINDOW DOWN OUTPUT SHORT TO GROUND When Monitored: Whenever the ignition is in the Run or Accessory position. Set Condition: When the BCM turns on the Driver Window Down circuit and detects a voltage of less than 0.5 volts for over 125 milliseconds, this code will set. POSSIBLE CAUSES DTC PRESENT MOTOR SHORTED DRIVER WINDOW DOWN DRIVER WIRE SHORT TO GROUND BODY CONTROL MODULE -DRIVER WINDOW DOWN DRIVER SHORTED TEST ACTION APPLICABILITY 1 Turn the ignition on. t, erase DTCs. Cycle the ignition switch from Off to Run. t, read DTCs. Does the DRBIII t display DRIVER WINDOW DOWN CIRCUIT SHORT TO GROUND? All Yes → Go To 2 No → The condition that caused the code to set is not present at this time. Using the wiring diagram/schematic as a guide, inspect the 2 Disconnect the Driver Window Motor connector. t, erase DTCs. Cycle the ignition switch from Off to Run. t, read DTCs. Does the DRBIII t display DRIVER WINDOW DOWN SHORTED TO GROUND? All Yes → Go To 3 No → Replace the Window Motor. Perform BODY VERIFICATION TEST - VER 1. 337 POWER WINDOWS |