Dodge Viper SRT-10 (ZB). Manual - part 337

 

  Index      Dodge     Dodge Viper SRT-10 (ZB) - service repair manual 2005 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  335  336  337  338   ..

 

 

Dodge Viper SRT-10 (ZB). Manual - part 337

 

 

TEST

ACTION

APPLICABILITY

3

Disconnect the Radio connector.
With the DRBIII

t, erase DTCs.

Cycle the ignition switch from OFF to ON.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display ACCESSORY RELAY CONTROL CIRCUIT SHORT TO

GROUND?

All

Yes

→ Go To 4

No

→ Replace the Radio.

Perform BODY VERIFICATION TEST - VER 1.

4

Turn the Ignition off.
Disconnect the Radio connector.
Remove the Accessory Relay from the PDC.
Disconnect the Body Control Module C4 connector.
Measure the resistance between ground and the Accessory Relay Control circuit.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Accessory Relay Control circuit for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

If there are no possible causes remaining, view repair.

All

Repair

Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.

241

IGNITION, POWER, ACCESSORY

BCM - ACCESSORY RELAY CONTROL CIRCUIT SHORT TO GROUND —

Continued

Symptom:

BCM - IGNITION MUX SWITCH INPUT MISMATCH

When Monitored and Set Condition:

BCM - IGNITION MUX SWITCH INPUT MISMATCH

When Monitored:

There are two inputs to the BCM from the Ignition Switch. The high

current Run/Start contact (non-MUX signal) of the ignition switch will make contact before
the low current Run contact (MUX signal).

Set Condition:

When the BCM detects the hardwire Run/Start circuit is active while

detecting the Ignition MUX circuit remains in the Lock/Acc/Unlock position for at least 2
seconds.

POSSIBLE CAUSES

FUSED IGNITION SWITCH OUTPUT (RUN-START) SHORT TO VOLTAGE

IGNITION SWITCH

FUSED IGNITION SWITCH (RUN-START) OUTPUT OPEN

BCM

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the BCM C2 harness connector.
Measure the voltage between the Fused Ignition Switch Output (Run-Start) circuit
and ground.
Is there any voltage present?

All

Yes

→ Repair the Fused Ignition Switch Output (Run-Start) circuit for a

short to voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn the ignition off.
Disconnect the BCM C2 harness connector.
Disconnect the Ignition Switch harness connector.
Measure the resistance of the Fused Ignition Switch Output (Run-Start) circuit
between the BCM C2 connector and the Ignition Switch connector.
Is the resistance above 5.0 ohms?

All

Yes

→ Repair the Fused Ignition Switch Output (Run - Start) circuit for

an open.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

242

IGNITION, POWER, ACCESSORY

TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the BCM C4 and C3 harness connectors.
Measure the resistance of the Ignition Switch using the following values:
Key Out: 20140 - 22460 ohms
Key In: 7790 - 8810 ohms
Accessory: 3131 - 3564 ohms
Unlock: 1472 - 1764 ohms
Run: 539 - 767 ohms
Did the Ignition Switch resistance measure within specifications for each position?

All

Yes

→ Replace and program the Body Control Module in accordance

with the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Ignition Switch in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

243

IGNITION, POWER, ACCESSORY

BCM - IGNITION MUX SWITCH INPUT MISMATCH —

Continued

Symptom:

BCM - IGNITION MUX SWITCH INPUT OPEN

When Monitored and Set Condition:

BCM - IGNITION MUX SWITCH INPUT OPEN

When Monitored:

Continuously.

Set Condition:

When the BCM detects the ignition switch MUX circuit voltage is above

4.7 volts for at least 2 seconds.

POSSIBLE CAUSES

IGNITION SWITCH SENSE CIRCUIT SHORT TO VOLTAGE

IGNITION SWITCH SENSE CIRCUIT OPEN

IGNITION SWITCH SENSE RETURN CIRCUIT OPEN

IGNITION SWITCH

BODY CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the Ignition Switch harness connector.
Disconnect the BCM C4 harness connector.
Measure the voltage between the Ignition Switch Sense circuit and ground.
Is the voltage above 5.00 volts?

All

Yes

→ Repair the Ignition Switch Sense circuit for a short to voltage.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn the ignition off.
Disconnect the Ignition Switch harness connector.
Disconnect the BCM C4 harness connector.
Measure the resistance of the Ignition Switch Sense circuit between the BCM C4
connector and the Ignition Switch connector.
Is the resistance above 5.0 ohms?

All

Yes

→ Repair the Ignition Switch Sense circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

3

Turn the ignition off.
Disconnect the Ignition Switch harness connector.
Disconnect the BCM C4 harness connector.
Measure the resistance of the Ignition Switch Sense Return circuit between the BCM
C4 connector and the Ignition Switch connector.
Is the resistance above 5.0 ohms?

All

Yes

→ Repair the Sense Return circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

244

IGNITION, POWER, ACCESSORY

 

 

 

 

 

 

 

Content   ..  335  336  337  338   ..