INSTRUMENTATION/DRIVER INFORMATION 9E – 19 DAEWOO V–121 BL4 Step No Yes Value(s) Action 6 1. If the problem is associated with only a single cluster indicator rather than all of the cluster 2. At the component, disconnect the wire from the instrument cluster indicator. 3. Connect a jumper wire between ground and the disconnected wire at the component. 4. Turn the ignition ON. Does the cluster indicator turn ON? Go to Step 7 Go to Step 10 7 Replace the faulty component (switch, sending unit, System OK 8 Check the connectors at the rear of the instrument Go to Step 10 Go to Step 9 9 Attach the connectors correctly. System OK 10 1. Disconnect the instrument cluster connectors. nector terminals A5, A18, and B6. (Consult the Is the voltage equal to the specified value? 11 – 14 v Go to Step 12 Go to Step 11 11 Repair the open circuit between the fuses and the in- System OK 12 Check the warning lamp bulbs. Go to Step 14 Go to Step 13 13 1. Replace any defective warning lamp bulbs. system to make sure that the generator is not 3. If a problem is found, repair the charging sys- tem. Is the repair complete? System OK 14 Use an ohmmeter to check for an open wire between Go to Step 15 Go to Step 16 15 Repair the open circuit between the instrument clus- System OK 16 Replace the instrument cluster. System OK
|