Symptom: CLUSTER WAKEUP OUTPUT SHORT - BCM When Monitored and Set Condition: CLUSTER WAKEUP OUTPUT SHORT - BCM When Monitored: Output is On. Set Condition: Feedback Sense high for 125 msec. (Excessive circuit load.) POSSIBLE CAUSES INSTRUMENT CLUSTER WAKE UP SIGNAL CIRCUIT SHORT TO GROUND BCM INSTRUMENT CLUSTER TEST ACTION APPLICABILITY 1 Turn the ignition off. t, erase DTCs. Turn the ignition off, wait 10 seconds, then turn the ignition on. t, read DTCs. Did this DTC reset? All Yes → If this DTC resets, replace the BCM in accordance with the Service Information. No → Go To 2 2 Turn the ignition off. All Yes → Repair the Instrument Cluster Wake Up Signal circuit for a short to ground. No → Replace the Instrument Cluster in accordance with the Service Information. 673 IGNITION, POWER, ACCESSORY |