A functioning converter would store this oxygen so it
can use it for the oxidation of HC and CO. As the
converter absorbs the oxygen, there will be a lack of
oxygen downstream of the converter. The output of
the downstream O2S will indicate limited activity in
this condition.
As the converter loses the ability to store oxygen,
the condition can be detected from the behavior of
the downstream O2S. When the efficiency drops, no
chemical reaction takes place. This means the con-
centration of oxygen will be the same downstream as
upstream. The output voltage of the downstream
O2S copies the voltage of the upstream sensor. The
only difference is a time lag (seen by the PCM)
between the switching of the O2S’s.
To monitor the system, the number of lean-to-rich
switches of upstream and downstream O2S’s is
counted.
The
ratio
of
downstream
switches
to
upstream switches is used to determine whether the
catalyst is operating properly. An effective catalyst
will have fewer downstream switches than it has
upstream switches i.e., a ratio closer to zero. For a
totally ineffective catalyst, this ratio will be one-to-
one, indicating that no oxidation occurs in the device.
The system must be monitored so that when cata-
lyst efficiency deteriorates and exhaust emissions
increase to over the legal limit, the MIL (check
engine lamp) will be illuminated.
Monitor Operation— To monitor catalyst effi-
ciency, the PCM expands the rich and lean switch
points of the heated oxygen sensor. With extended
switch points, the air/fuel mixture runs richer and
leaner to overburden the catalytic converter. Once
the test is started, the air/fuel mixture runs rich and
lean and the O2 switches are counted. A switch is
counted when an oxygen sensor signal goes from
below the lean threshold to above the rich threshold.
The number of Rear O2 sensor switches is divided by
the number of Front O2 sensor switches to determine
the switching ratio.
The test runs for 20 seconds. As catalyst efficiency
deteriorated over the life of the vehicle, the switch
rate at the downstream sensor approaches that of the
upstream sensor. If at any point during the test
period the switch ratio reaches a predetermined
value, a counter is incremented by one. The monitor
is enabled to run another test during that trip. When
the test fails three times, the counter increments to
three, a malfunction is entered, and a Freeze Frame
is stored. When the counter increments to three dur-
ing the next trip, the code is matured and the MIL is
illuminated. If the test passes the first, no further
testing is conducted during that trip.
The MIL is extinguished after three consecutive
good trips. The good trip criteria for the catalyst
monitor is more stringent than the failure criteria. In
order to pass the test and increment one good trip,
the downstream sensor switch rate must be less than
80% of the upstream rate (60% for manual transmis-
sions). The failure percentages are 90% and 70%
respectively.
Enabling Conditions— The following conditions
must typically be met before the PCM runs the cat-
alyst monitor. Specific times for each parameter may
be different from engine to engine.
• Accumulated drive time
• Enable time
• Ambient air temperature
• Barometric pressure
• Catalyst warm-up counter
• Engine coolant temperature
• Accumulated throttle position sensor
• Vehicle speed
• MAP
• RPM
• Engine in closed loop
• Fuel level
Pending Conditions—
• Misfire DTC
• Front Oxygen Sensor Response
• Front Oxygen Sensor Heater Monitor
• Front Oxygen Sensor Electrical
• Rear Oxygen Sensor Rationality (middle check)
• Rear Oxygen Sensor Heater Monitor
• Rear Oxygen Sensor Electrical
• Fuel System Monitor
• All TPS faults
• All MAP faults
• All ECT sensor faults
• Purge flow solenoid functionality
• Purge flow solenoid electrical
• All PCM self test faults
• All CMP and CKP sensor faults
• All injector and ignition electrical faults
• Idle Air Control (IAC) motor functionality
• Vehicle Speed Sensor
• Brake switch
• Intake air temperature
Conflict— The catalyst monitor does not run if
any of the following are conditions are present:
• EGR Monitor in progress
• Fuel system rich intrusive test in progress
• EVAP Monitor in progress
• Time since start is less than 60 seconds
• Low fuel level
• Low ambient air temperature
Suspend— The Task Manager does not mature a
catalyst fault if any of the following are present:
• Oxygen Sensor Monitor, Priority 1
• Upstream Oxygen Sensor Heater, Priority 1
• EGR Monitor, Priority 1
• EVAP Monitor, Priority 1
JX
EMISSION CONTROL SYSTEMS
25 - 23
DESCRIPTION AND OPERATION (Continued)