02 *01 − − − − YES NO YES NO 17-38 EPS Components NEP (BLU) EPS CONTROL UNIT CONNECTOR D (28P) EPS CONTROL UNIT CONNECTOR D (28P) ECM/PCM CONNECTOR A (44P) NEP (BLU) NEP (BLU) 9. Turn the ignition switch to LOCK (0). 10. Short the SCS line with the HDS. 11. Disconnect ECM/PCM connector A (44P). 12. Check for continuity between EPS control unit connector D (28P) terminal No. 3 and body ground. Repair short to body ground in the wire between the EPS control unit and the ECM/PCM. Go to step 13. 13. Check for continuity between EPS control unit connector D (28P) terminal No. 3 and ECM/PCM Update the ECM/PCM if it does not have the latest software (see page 11-227), or substitute a Repair open in the wire between the EPS control unit and the ECM/PCM. Wire side of female terminals Wire side of female terminals Terminal side of female terminals Is ther e continuity? Is ther e continuity? 08/08/21 14:54:04 61SNR030_170_0039 |