FANUC Series 30i/300i/300is-MODEL A. Machining Center System. User's manual - page 261

 

  Index      Manuals     FANUC Series 30i/300i/300is-MODEL A. Machining Center System. User's manual (B-63944EN/03)

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

 

 

Content      ..     259      260      261      262     ..

 

 

 

FANUC Series 30i/300i/300is-MODEL A. Machining Center System. User's manual - page 261

 

 

A.PARAMETERS

 APPENDIX 

B-63944EN/03

 

 

- 2044 - 

        # 5 

DRC

  When relative positions are displayed: 

0:  Values not excluding the amount of travel based on tool radius 

 

tool nose radius compensation are displayed. 

1:  Values excluding the amount of travel based on tool radius 

 tool 

nose radius compensation (programmed positions) are displayed. 

 

        # 6 

DAL

 Absolute 

position 

0:  The actual position displayed takes into account tool length 

offset. 

1:  The programmed position displayed does not take into account 

tool length offset. 

 

NOTE 

 

In lathe systems, whether to exclude a tool offset 
when displaying the absolute position is 
determined by the setting of bit 1 (DAP) of 
parameter No. 3129. 

 

        # 7 

DAC

  When an absolute position are displayed: 

0:  Values not excluding the amount of travel based on tool radius 

 

tool nose radius compensation are displayed. 

1:  Values excluding the amount of travel based on tool radius 

 tool 

nose radius compensation (programmed positions) are displayed. 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3106 

 

 

DAK 

      

 

 

[Input type]  Setting input 

 [Data 

type] 

Bit 
 

        # 6 

DAK

  Specifies whether to display coordinates in the program coordinate 

system or workpiece coordinate system as absolute coordinates when 
the three-dimensional coordinate conversion mode, the tilted working 
plane command mode or the workpiece setting error compensation 
mode is set. 
0:  Display coordinates in the program coordinate system. 
1:  Display coordinates in the workpiece coordinate system. 
 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3111    

OPS  OPM 

 

 

 

SPS  SVS 

 

 

[Input type]  Setting input 

 

[Data type]  Bit path 

 

        # 0 

SVS

  Servo setting screen and servo tuning screen   

0: Not 

displayed 

1: Displayed 
 

        # 1 

SPS

  Spindle tuning screen 

0: Not 

displayed 

1: Displayed 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 2045 - 

 

        # 5 

OPM

 Operating 

monitor 

0: Not 

displayed 

1: Displayed 
 

        # 6 

OPS

  The speedometer on the operating monitor screen indicates: 

0:  Spindle motor speed 
1: Spindle 

speed 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3115 

 

      

NDAx 

NDPx

 

 

[Input type]  Parameter input 

 

[Data type]  Bit axis 

 

        # 0 

NDPx

  The current position is: 

0: Displayed. 
1: Not 

displayed. 

 

NOTE 

 

When using the electric gear box (EGB) function, 
set 1 for the EGB dummy axis to disable current 
position display. 

 

    # 1 

NDAx

  The current position and the amount of the movement to be made in 

absolute and relative coordinates are: 
0: Displayed. 
1: Not 

displayed. 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

 

      

DAP 

DRP 

3129 

 

 

 

 

 

 

 

 

 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

        # 0 

DRP

  For relative coordinate display: 

0:  The actual position considering a tool offset (tool movement) is 

displayed. 

1:  The programmed position excluding a tool offset (tool 

movement) is displayed. 

 

A.PARAMETERS

 APPENDIX 

B-63944EN/03

 

 

- 2046 - 

        # 1 

DAP

  For absolute coordinate display: 

0:  The actual position considering a tool offset (tool movement) is 

displayed. 

1:  The programmed position excluding a tool offset (tool 

movement) is displayed. 

 

NOTE 

 

In machining center systems, whether to exclude 
the tool length offset when displaying the absolute 
position is determined according to the setting of bit 
6 (DAL) of parameter No. 3104. 

 

3131 

 

Subscript of axis name 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte axis 

  [Valid data range]  0 to 9, 65 to 90 

In order to distinguish axes under parallel operation, synchronization 
control, and tandem control, specify a subscript for each axis name. 
 

Setting value 

Meaning 

Each axis is set as an axis other than a parallel axis, 
synchronization control axis, and tandem control axis. 

1 to 9 

A set value is used as a subscript. 

65 to 90 

A set letter (ASCII code) is used as a subscript. 

 
Example)  When the axis name is X, a subscript is added as 
indicated below. 
 

Setting value 

Axis name displayed on a screen such as the 

position display screen 

0 X 
1 X1 

77 XM 
83 XS 

 
If a multi-path system is used, no extended axis name is used within a 
path, and no subscript is set for the axis names, then the path number 
is automatically used as the subscript for the axis names. To disable 
the display of axis name subscripts, set a blank (32) of ASCII code in 
the parameter for specifying an axis name subscript. 
 

NOTE 

 

If even one axis in a path uses an extended axis 
name when bit 2 (EAS) of parameter No. 11308 is 
set to 0, subscripts cannot be used for axis names 
in the path. 

 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 2047 - 

3141 

 

Path name (1st character) 

 

3142 

 

Path name (2nd character) 

 

3143 

 

Path name (3rd character) 

 

3144 

 

Path name (4th character) 

 

3145 

 

Path name (5th character) 

 

3146 

 

Path name (6th character) 

 

3147 

 

Path name (7th character) 

 

 

[Input type]  Parameter input 

 

[Data type]  Byte path 

  [Valid data range]  See the character-code correspondence table. 

Specify a path name with codes. 
Any character string consisting of alphanumeric characters, katakana 
characters, and special characters with a maximum length of seven 
characters can be displayed as a series name. 
 

NOTE 

1  For characters and codes, see Appendix A, 

“CHARACTER CODE LIST”. 

2  When 0 is set in parameter No. 3141, 

PATH1(,PATH2...) are displayed as path names. 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3201 

 

 

NPE 

      

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

        # 6 

NPE

  With an M02, M30, or M99 block, program registration is assumed to 

be: 
0: Completed 
1: Not 

completed 

 

A.PARAMETERS

 APPENDIX 

B-63944EN/03

 

 

- 2048 - 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3202 

 

   

NE9 

   

NE8 

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

        # 0 

NE8

  Editing of subprograms with program numbers 8000 to 8999 

0: Not 

inhibited 

1: Inhibited 
When this parameter is set to 1, the following editing operations are 
disabled: 
(1)  Program deletion (Even when deletion of all programs is 

specified, programs with program numbers 8000 to 8999 are not 
deleted.) 

(2)  Program output (Even when outputting all programs is specified, 

programs with program numbers 8000 to 8999 are not output.) 

(3)  Program number search 
(4)  Program editing of registered programs 
(5) Program 

registration 

(6) Program 

collation 

(7) Displaying 

programs 

 

NOTE 

 

This parameter setting does not affect the following 
programs: 

(1)  Programs on the Data Server 
(2)  Programs for running and editing memory card 

programs on a memory card 

 

        # 4 

NE9

  Editing of subprograms with program numbers 9000 to 9999 

0: Not 

inhibited 

1: Inhibited 
When this parameter is set to 1, the following editing operations are 
disabled: 
(1)  Program deletion (Even when deletion of all programs is 

specified, programs with program numbers 9000 to 9999 are not 
deleted.) 

(2)  Program output (Even when outputting all programs is specified, 

programs with program numbers 9000 to 9999 are not output.) 

(3)  Program number search 
(4)  Program editing of registered programs 
(5) Program 

registration 

(6) Program 

collation 

(7) Displaying 

programs 

 

NOTE 

 

This parameter setting does not affect the following 
programs: 

(1)  Programs on the Data Server 
(2)  Programs for running and editing memory card 

programs on a memory card 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 2049 - 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3203 

 

MCL 

MER 

MZE 

     

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

        # 5 

MZE

  After MDI operation is started, program editing during operation is: 

0: Enabled 
1: Disabled 
 

        # 6 

MER

  When the last block of a program has been executed at single block 

operation in the MDI mode, the executed block is: 
0: Not 

deleted 

1: Deleted 

 

 

NOTE 

 

When MER is set to 0, the program is deleted if the 
end-of-record mark (%) is read and executed. (The 
mark % is automatically inserted at the end of a 
program.) 

 

        # 7 

MCL

  Whether a program prepared in the MDI mode is cleared by reset 

0: Not 

deleted 

1: Deleted 

 

 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3204 

 

 

MKP 

      

 

 

[Input type]  Parameter input 

 

[Data type]  Bit path 

 

        # 6 

MKP

  When M02, M30, or EOR(%) is executed during MDI operation, the 

created MDI program is: 
0: Erased 

automatically. 

1:  Not erased automatically. 
 

NOTE 

 

If the bit 6 (MER) of parameter No. 3203 is 1, 
executing the last block provides a choice of 
whether to automatically erase a created program. 

 

A.PARAMETERS

 APPENDIX 

B-63944EN/03

 

 

- 2050 - 

  

#7 #6 #5 #4 #3 #2 #1 #0 

3207 

 

  

VRN 

     

 

 

[Input type]  Parameter input 

 [Data 

type] 

Bit 
 

        # 5 

VRN

  On the custom macro variable screen, the variable names of common 

variables #500 to #549 are: 
0: Not 

displayed. 

1: Displayed. 
 

3210 

 

Program protection (PSW) 

 

 

[Input type]  Parameter input 

 [Data 

type] 

2-word 

  [Valid data range]  0 to 99999999 

This parameter sets a password for protecting program Nos. 9000 to 
9999. When a value other than zero is set in this parameter and this 
value differs from the keyword set in parameter No.3211, bit 4 (NE9) 
of parameter No.3202 for protecting program Nos. 9000 to 9999 is 
automatically set to 1.   
This disables the editing of program Nos. 9000 to 9999. Until the 
value set as the password is set as a keyword, NE9 cannot be set to 0 
and the password cannot be modified. 
 

NOTE 

1  The state where password 

 0 and password 

 

keyword is referred to as the locked state. When an 
attempt is made to modify the password by MDI 
input operation in this state, the warning message 
"WRITE PROTECTED" is displayed to indicate that 
the password cannot be modified. When an 
attempt is made to modify the password with G10 
(programmable parameter input), alarm (PS0231) 
is issued. 

2  When the value of the password is not 0, the 

parameter screen does not display the password. 
Care must be taken in setting a password. 

 

B-63944EN/03

 APPENDIX 

A.PARAMETERS

 

 

- 2051 - 

3211 

 

Program protection key (KEY) 

 

 

[Input type]  Parameter input 

 [Data 

type] 

2-word 

  [Valid data range]  0 to 99999999 

When the value set as the password (set in parameter No.3210) is set 
in this parameter, the locked state is released and the user can now 
modify the password and the value set in bit 4 (NE9) of parameter 
No.3202. 
 

NOTE 

 

The value set in this parameter is not displayed. 
When the power is turned off, this parameter is set 
to 0. 

 

3220  

Password 

(PSW) 

 

 

[Input type]  Locked parameter 

 [Data 

type] 

2-word 

  [Valid data range]  0 to 99999999 

This parameter sets a password (PSW). When a value other than 0 is 
set, a password is set. When a password is set, a blank is displayed in 
this parameter, and the state (locked state) where an operation such as 
program editing is locked is set. When password (PSW) = 0, namely, 
in the normal state, or when password (PSW) = keyword (KEY), 
namely, in the unlock state, this parameter can be set. 
 

3221  

Keyword 

(KEY) 

 

 

[Input type]  Locked parameter 

 [Data 

type] 

2-word 

  [Valid data range]  0 to 99999999 

When the same value as the password (PSW) is set in this parameter, 
the lock is released (unlock state). The value set in this parameter is 
not displayed. 
The value of this parameter is initialized to 0 automatically when the 
power is turned on. So, if the power is turned off in the unlock state 
then is turned on again, the lock state is automatically set. 
 

 

 

 

 

 

 

 

Content      ..     259      260      261      262     ..