8.DATA INPUT/OUTPUT

 OPERATION 

B-63944EN/03

 

 

- 1308 - 

8.3.2 

Inputting and Outputting Parameters 

 
Parameters can be input and output using the ALL IO screen. 
 

Inputting parameters (for 7.2/8.4/10.4-inch display unit) 

Procedure 

Press the function key 

Press the continuous menu key 

 until soft key [SETTING] 

appears. 
Press the soft key [SETTING].   

Press the MDI switch on the machine operator’s panel or enter 
state emergency stop. 

Enter 1 in response to the prompt for “PARAMETER WRITE” 
in setting data.Alarm SW0100 appears. 

Press the soft key [PARAMETER] on the ALL IO screen. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the soft key [(OPRT)]. 

Press the soft key [N READ]. 

Set the name of the file that you want to input. 
Type a file name, and press the soft key [F NAME]. 
If the input file name is omitted, default input file name 
“CNC-PARA.TXT” is assumed. 

10  Press the soft key [EXEC]. 

This starts reading the parameter, and “INPUT” blinks in the 
lower right part of the screen. When the read operation ends, the 
“INPUT” indication disappears. 
To cancel the input of the program, press the soft key [CAN]. 

11  Press the function key 

12  Press the soft key [SETTING].   
13  Press the MDI switch on the machine operator’s panel or enter 

state emergency stop. 

14  Enter 0 in response to the prompt for “PARAMETER WRITE” 

in setting data. 

15  Turn the power of the CNC on again. 
 

B-63944EN/03

 OPERATION 

8.DATA INPUT/OUTPUT

 

 

- 1309 - 

 

Inputting parameters (for 15-inch display unit) 

Procedure 

Press the function key 

Press the vertical soft key [NEXT PAGE] until vertical soft key 
[SETTING] appears. 
Press the vertical soft key [SETTING].   

Press the MDI switch on the machine operator’s panel or enter 
state emergency stop. 

Enter 1 in response to the prompt for “PARAMETER WRITE” 
in setting data.Alarm SW0100 appears. 

On the ALL IO screen, press the vertical soft key [NEXT PAGE] 
until vertical soft key [PARAMETER] appears. 
Press the vertical soft key [PARAMETER].   

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the horizontal soft key [N READ]. 

Set the name of the file that you want to input. 
Type a file name, and press the horizontal soft key [F NAME]. 
If the input file name is omitted, default input file name 
“CNC-PARA.TXT” is assumed. 

Press the horizontal soft key [EXEC]. 
This starts reading the parameter, and “INPUT” blinks in the 
lower right part of the screen. When the read operation ends, the 
“INPUT” indication disappears. 
To cancel the input of the program, press the horizontal soft key 
[CAN]. 

10  Press the function key 

11  Press the vertical soft key [SETTING].   
12  Press the MDI switch on the machine operator

s panel or enter 

state emergency stop. 

13  Enter 0 in response to the prompt for “PARAMETER WRITE” 

in setting data. 

14  Turn the power of the CNC on again. 
 

8.DATA INPUT/OUTPUT

 OPERATION 

B-63944EN/03

 

 

- 1310 - 

 

Outputting parameters (for 7.2/8.4/10.4-inch display unit) 

Procedure 

Press the soft key [PARAMETER] on the ALL IO screen. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the soft key [(OPRT)]. 

Press the soft key [PUNCH].

 

 

Set the file name to be output. 
Type a file name, and press the soft key [F NAME]. 
If the file name is omitted, default file name “CNC-PARA.TXT” 
is assumed. 

Press the soft key [EXEC]. 
This starts outputting the parameter, and “OUTPUT” blinks in 
the lower right part of the screen. When the read operation ends, 
the “OUTPUT” indication disappears. 
To cancel the output, press the soft key [CAN]. 

 

Outputting parameters (for 15-inch display unit) 

Procedure 

On the ALL IO screen, press the vertical soft key [NEXT PAGE] 
until vertical soft key [PARAMETER] appears. 
Press the vertical soft key [PARAMETER].   

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the horizontal soft key [PUNCH]. 

Set the file name to be output. 
Type a file name, and press the horizontal soft key [F NAME]. 
If the file name is omitted, default file name “CNC-PARA.TXT” 
is assumed. 

Press the horizontal soft key [EXEC]. 
This starts outputting the parameter, and “OUTPUT” blinks in 
the lower right part of the screen. When the read operation ends, 
the “OUTPUT” indication disappears. 
To cancel the output, press the horizontal soft key [CAN]. 

 

B-63944EN/03

 OPERATION 

8.DATA INPUT/OUTPUT

 

 

- 1311 - 

8.3.3 

Inputting and Outputting Offset Data 

 
Offset data can be input and output using the ALL IO screen. 
 

Inputting offset data (for 7.2/8.4/10.4-inch display unit) 

Procedure 

Press the soft key [OFFSET] on the ALL IO screen. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the soft key [(OPRT)]. 

Press the soft key [N READ]. 

Set the name of the file that you want to input. 
Type a file name, and press the soft key [F NAME]. 
If the input file name is omitted, default input file name 
“TOOLOFST.TXT” is assumed. 

Press the soft key [EXEC]. 
This starts reading the offset data, and “INPUT” blinks in the 
lower right part of the screen. When the read operation ends, the 
“INPUT” indication disappears. 
To cancel the input of the program, press the soft key [CAN]. 

 

Inputting offset data (for 15-inch display unit) 

Procedure 

On the ALL IO screen, press the vertical soft key [NEXT PAGE] 
until vertical soft key [OFFSET] appears. 
Press the vertical soft key [OFFSET]. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the horizontal soft key [N READ]. 

Set the name of the file that you want to input. 
Type a file name, and press the horizontal soft key [F NAME]. 
If the input file name is omitted, default input file name 
“TOOLOFST.TXT” is assumed. 

Press the horizontal soft key [EXEC]. 
This starts reading the offset data, and “INPUT” blinks in the 
lower right part of the screen. When the read operation ends, the 
“INPUT” indication disappears. 
To cancel the input of the program, press the horizontal soft key 
[CAN]. 

 

8.DATA INPUT/OUTPUT

 OPERATION 

B-63944EN/03

 

 

- 1312 - 

 

Outputting offset data (for 7.2/8.4/10.4-inch display unit) 

Procedure 

Press the soft key [OFFSET] on the ALL IO screen. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the soft key [(OPRT)]. 

Press the soft key [PUNCH].   

Set the file name to be output. 
Type a file name, and press the soft key [F NAME]. 
If the file name is omitted, default file name “TOOLOFST.TXT” 
is assumed. 

Press the soft key [EXEC]. 
This starts outputting the offset data, and “OUTPUT” blinks in 
the lower right part of the screen. When the read operation ends, 
the “OUTPUT” indication disappears. 
To cancel the output, press the soft key [CAN]. 

 

Outputting offset data (for 15-inch display unit) 

Procedure 

On the ALL IO screen, press the vertical soft key [NEXT PAGE] 
until vertical soft key [OFFSET] appears. 
Press the vertical soft key [OFFSET]. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the horizontal soft key [PUNCH].   

Set the file name to be output. 
Type a file name, and press the horizontal soft key [F NAME]. 
If the file name is omitted, default file name “TOOLOFST.TXT” 
is assumed. 

Press the horizontal soft key [EXEC]. 
This starts outputting the offset data, and “OUTPUT” blinks in 
the lower right part of the screen. When the read operation ends, 
the “OUTPUT” indication disappears. 
To cancel the output, press the horizontal soft key [CAN]. 

 

B-63944EN/03

 OPERATION 

8.DATA INPUT/OUTPUT

 

 

- 1313 - 

8.3.4 

Inputting/Outputting Pitch Error Compensation Data 

 
Pitch error compensation data can be input and output using the ALL 
IO screen. 
 

Inputting pitch error compensation data (for 7.2/8.4/10.4-inch display unit) 

Procedure 

Press the function key 

Press the continuous menu key 

 until soft key [SETTING] 

appears. 
Press the soft key [SETTING].   

Press the MDI switch on the machine operator’s panel or enter 
state emergency stop. 

Enter 1 in response to the prompt for “PARAMETER WRITE” 
in setting data.Alarm SW0100 appears. 

Press the soft key [PITCH] on the ALL IO screen. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the soft key [(OPRT)]. 

Press the soft key [N READ]. 

Set the name of the file that you want to input. 
Type a file name, and press the soft key [F NAME]. 
If the input file name is omitted, default input file name 
“PITCH.TXT” is assumed. 

10  Press the soft key [EXEC]. 

This starts reading the pitch error compensation data, and 
“INPUT” blinks in the lower right part of the screen. When the 
read operation ends, the “INPUT” indication disappears. 
To cancel the input of the program, press the soft key [CAN]. 

11  Press the function key 

12  Press the soft key [SETTING].   
13  Press the MDI switch on the machine operator’s panel or enter 

state emergency stop. 

14  Enter 0 in response to the prompt for “PARAMETER WRITE” 

in setting data. 

15  Turn the power of the CNC on again. 
 

8.DATA INPUT/OUTPUT

 OPERATION 

B-63944EN/03

 

 

- 1314 - 

 

Inputting pitch error compensation data (for 15-inch display unit) 

Procedure 

Press the function key 

Press the vertical soft key [NEXT PAGE] until vertical soft key 
[SETTING] appears. 
Press the vertical soft key [SETTING].   

Press the MDI switch on the machine operator’s panel or enter 
state emergency stop. 

Enter 1 in response to the prompt for “PARAMETER WRITE” 
in setting data.Alarm SW0100 appears. 

On the ALL IO screen, press the vertical soft key [NEXT PAGE] 
until vertical soft key [PITCH ERROR] appears. 
Press the vertical soft key [PITCH ERROR].   

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the horizontal soft key [N READ]. 

Set the name of the file that you want to input. 
Type a file name, and press the horizontal soft key [F NAME]. 
If the input file name is omitted, default input file name 
“PITCH.TXT” is assumed. 

Press the horizontal soft key [EXEC]. 
This starts reading the pitch error compensation data, and 
“INPUT” blinks in the lower right part of the screen. When the 
read operation ends, the “INPUT” indication disappears. 
To cancel the input of the program, press the horizontal soft key 
[CAN]. 

10  Press the function key 

11  Press the vertical soft key [SETTING].   
12  Press the MDI switch on the machine operator’s panel or enter 

state emergency stop. 

13  Enter 0 in response to the prompt for “PARAMETER WRITE” 

in setting data. 

14  Turn the power of the CNC on again. 
 

B-63944EN/03

 OPERATION 

8.DATA INPUT/OUTPUT

 

 

- 1315 - 

Outputting pitch error compensation data (for 7.2/8.4/10.4-inch display unit) 

Procedure 

Press the soft key [PITCH] on the ALL IO screen. 

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the soft key [(OPRT)]. 

Press the soft key [PUNCH].   

Set the file name to be output. 
Type a file name, and press the soft key [F NAME]. 
If the file name is omitted, default file name “PITCH.TXT” is 
assumed. 

Press the soft key [EXEC]. 
This starts outputting the pitch error compensation data, and 
“OUTPUT” blinks in the lower right part of the screen. When the 
read operation ends, the “OUTPUT” indication disappears. 
To cancel the output, press the soft key [CAN]. 

 

Outputting pitch error compensation data (for 15-inch display unit) 

Procedure 

On the ALL IO screen, press the vertical soft key [NEXT PAGE] 
until vertical soft key [PITCH ERROR] appears. 
Press the vertical soft key [PITCH ERROR].   

Press the EDIT switch on the machine operator’s panel or enter 
state emergency stop. 

Press the horizontal soft key [PUNCH].   

Set the file name to be output. 
Type a file name, and press the horizontal soft key [F NAME]. 
If the file name is omitted, default file name “PITCH.TXT” is 
assumed. 

Press the horizontal soft key [EXEC]. 
This starts outputting the pitch error compensation data, and 
“OUTPUT” blinks in the lower right part of the screen. When the 
read operation ends, the “OUTPUT” indication disappears. 
To cancel the output, press the horizontal soft key [CAN]. 

 

 

 

 

 

 

 

 

Content      ..     167      168      169      170     ..