1. AXIS CONTROL
B-64693EN-1/01
- 218 -
#0 NDPx The current position is: 0: Displayed. 1: Not displayed.
#1 NDAx The current position and the amount of the movement to be made in absolute and relative coordinates are: Displayed. 1: Not displayed.
3130
Axis display order for current position display screens
[Input type] Parameter input
[Data type] Byte axis [Valid data range] 0 to 32 Set the order in which axes are displayed on current position display screens (absolute, 3131
Subscript of axis name
[Input type] Parameter input
[Data type] Byte axis [Valid data range] 0 to 9, 65 to 90 In order to distinguish axes under synchronization control and tandem control, specify a Setting value Meaning 0 Each axis is set as an axis other than a synchronization control axis and 1 to 9 A set value is used as a subscript. 65 to 90 A set letter (ASCII code) is used as a subscript.
[Example] When the axis name is X, a subscript is added as indicated below. Setting value Axis name displayed on a screen such as the position display screen 0 X 1 X1 77 XM 83 XS NOTE
If even one axis in a path uses an extended axis name when bit 2
#7 #6 #5 #4 #3 #2 #1 #0 8301
SYA
[Input type] Parameter input
[Data type] Bit path
|