Technical Specifications
7.2 Optical Interface Performance
7.2.1 SDH optical Interface
The performance of the STM-1 optical interface of the OptiX OSN 3500 is shown in
Table 7-2.
Table 7-2 Performance of the STM-1 optical interface of the OptiX OSN 3500
Nominal bit rate
155520kbit/s
Classification code
I-1
S-1.1
L-1.1
L-1.2
Ve-1.2
Working wavelength (nm)
1310
1310
1310
1550
1550
Source type
LED
MLM
SLM
SLM
SLM
Transmitter at reference
point S
Optical path between
G.957-compli
G.957-compli
G.957-compli
G.957-compli
Refer to
Point S and R
ant
ant
ant
ant
G.957 *
Receiver at reference
point R
*: Formulated by basic rules, though adjustment and optimization are made to part of the parameters.
The performance of the STM-4 optical interface of the OptiX OSN 3500 is shown in
Table 7-3.
Table 7-3 Performance of the STM-4 optical interface of the OptiX OSN 3500
Nominal bit rate
622080kbit/s
Classification code
I-4
S-4.1
L-4.1
L-4.2
Ve-4.2
Working wavelength
1310
1310
1310
1550
1550
(nm)
Source type
LED/MLM
MLM
MLM/SLM
SLM
SLM
Transmitter at reference
point S
Optical path between
G.957-
G.957-
G.957-
G.957-
Refer to
Point S and R
compliant
compliant
compliant
compliant
G.957*
Receiver at reference
point R
*: Formulated by basic rules, though adjustment and optimization are made to part of the parameters.
The performance of the STM-16 optical interface of the OptiX OSN 3500 is shown in
Table 7-4.
7-2
Technical Specifications
Table 7-4 Performance of the STM-16 optical interface of the OptiX OSN 3500
Nominal
2488320kbit/s
bit rate
Color
Classificati
L-
V-
U-
I-16
S-16.1
L-16.1
L-16.2
optical
on code
16.2Je
16.2Je
16.2Je
interface
Working
Fixed
wavelength
1310
1310
1310
1550
1550
1550
1550
wavelength
(nm)
Source type
MLM
SLM
SLM
SLM
SLM
SLM
SLM
SLM
Transmitter
at reference
point S
Optical
path
In
Refer
Refer to
G.957-
G.957-
G.957-
Refer to
Refer to
between
compliance
to
G.692 and
compliant
compliant
compliant
G.957*
G.957*
Point S and
with G.957
G.957*
G.691*
R
Receiver at
reference
point R
*: Formulated by basic rules, though adjustment and optimization are made to part of the parameters.
The performance of the STM-64 optical interface of the OptiX OSN 3500 is shown in
Table 7-5.
7-3
Technical Specifications
Table 7-5 Performance of the STM-64 optical interface of the OptiX OSN 3500
Nominal bit rate
9953280kbit/s
I-64.1
S-64.2b
L-64.2b
Le-64.2
Ls-64.2
V-64.2b
Color
Classification
optical
code
interface
Working
1550
1550
1550
1550
1550
1550
Fixed
wavelength
wavelengt
(nm)
h
Source type
SLM
SLM
SLM
SLM
SLM
SLM
SLM
Transmitter at
G.691-
G.691-
G.691-
G.691-
G.691-
G.691-
Refer to
reference point
compliant
compliant
compliant
compliant
compliant
compliant
G.692 and
S
G.691*
Optical path
between Point S
and R
Receiver at
reference point
R
*: Formulated by basic rules, though adjustment and optimization are made to part of the parameters.
7.2.2 GE Optical Interface
The performance of the GE optical interface of the OptiX OSN 3500 conforms to IEEE
802.3z, as shown in Table 7-6.
7-4
Technical Specifications
Table 7-6 Specifications of GE optical interface of the OptiX OSN 3500
Parameter
Type
Range
Unit
Value
Minimum
transmitting
dBm
-9.5
optical power
1000Base-SX
Maximum
transmitting
dBm
-4
optical power
Optical
power
Minimum
transmitting
dBm
-11.5
optical power
1000Base-LX
Maximum
transmitting
dBm
-3
optical power
Maximum value
nm
770
1000Base-SX
Minimum value
nm
860
Central
wavelength
Maximum value
nm
1355
1000Base-LX
Minimum value
nm
1270
1000Base-SX
Maximum value
dBm
0
overload
power
1000Base-LX
Maximum value
dBm
-3
1000Base-SX
Minimum value
dBm
-17
Receiver
sensitivity
1000Base-LX
Minimum value
dBm
-19
1000Base-SX
Minimum value
dB
9
Extinction
ratio
1000Base-LX
Minimum value
dB
9
7-5
Technical Specifications
7.3 Electrical Interface Performance
7.3.1 PDH Electrical Interface
Table 7-7 lists the PDH electrical interface performance of the OptiX OSN 3500.
Table 7-7 Performance of the PDH electrical interface
Type
1544kbit/s
2048kbit/s
34368kbit/s
44736kbit/s
139264kbit/s
155520kbit/s
B8ZS code
HDB3
Code pattern
or AMI
HDB3 code
B3ZS code
CMI code
CMI code
code
code
Bit rate of
signals at
output port
Attenuation
tolerance at
G.703-
G.703-
G.703-
G.703-
input port
compliant
compliant
compliant
compliant
G.703-
G.703-
Frequency
compliant
compliant
deviation
tolerance at
input port
Anti-interfere
nce capability
-
-
-
-
of input port
7-6
Technical Specifications
7.4 Timing and Synchronization
Performance
7.4.1 Clock Interface Type
Table 7-8 lists clock features of the OptiX OSN 3500.
Table 7-8 Clock features of the OptiX OSN 3500
External
synchronizatio
Two inputs, 2048kbit/s (G.703 6) or 2048kHz (G.703 10), 75
n source
Synchronizatio
two outputs, 2048kbit/s (G.703 §6) or 2048kHz (G.703 §10), 75
n output
7.4.2 Timing and Synchronization Performance
Table 7-9 lists the timing and synchronization performance of the OptiX OSN 3500.
Table 7-9 Timing and synchronization performance of the OptiX OSN 3500
Long-term phase
Output frequency of internal
Output jitter
variation (in locked
oscillator in free-run mode
mode)
G.813-compliant
G.813-compliant
G.813-compliant
7-7
Technical Specifications
7.5 Transmission Performance
Table 7-10 lists the transmission performance of the OptiX OSN 3500.
Table 7-10 Transmission performance of the OptiX OSN 3500
Jitter at STM-N
Jitter at PDH interface
Bit errors
interface
G.813/G.825-compliant
G.823/G.783-compliant
G.826-compliant
7-8
Technical Specifications
7.6 Power Consumption
Table 7-11 lists the board power consumption of the OptiX OSN 3500.
Table 7-11 Board power consumption of the OptiX OSN 3500
Power
Power
Board
consumption
Board
consumption (W)
(W)
SL64
32
BA2
20
SL16
20
BPA
20
SLQ4
16
DCU
0
SLD4
16
SPQ4
24
SL4
16
PD3
19
SLQ1
14
PL3
15
SLD1
14
D34S
2
SL1
14
PQM
22
SEP1
17
PQ1
19
EU08
11
D75S
5.5
OU08
6
D12S
9
EU04
6
TSB4
2.5
GXCS
27
TSB8
5
EXCS
62
EGS2
39
SCC
10
EFS0
33
AUX
19
ETF8
2
AFB
0
EFS4
33
7-9
Technical Specifications
7.7 Electromagnetic Compatibility
The OptiX OSN 3500 equipment is designed in accordance with the ETS300 386
series and ETS 300127 standards stipulated by the European Telecommunications
Standard Institute (ETSI) , and has passed EMC-related tests. Table 7-12 lists the
EMC test indices of the OptiX OSN 3500.
Table 7-12 EMC test indices of the OptiX OSN 3500
Item
Standard
Result
Conducted emission
EN55022 Class A
Passed
Radiated emission
EN55022 Class A
Passed
IEC1000-4-2 (Air
Electrostatic discharge
discharge:8KV;Contact
Passed
discharge:6KV)
Immunity to radiated electromagnetic
IEC1000-4-3 (10V/m)
Passed
fields
Electrical transient/burst immunity
IEC1000-4-4 (2kV)
Passed
Inject current immunity
IEC1000-4-6 (3V)
Passed
7-10
Technical Specifications
7.8 Environmental Index
Table 7-13 lists the environmental indices with which efficient operation of the OptiX
OSN 3500 can be guaranteed.
Table 7-13 Environmental indices
Altitude
4000m
Air pressure
70 ~ 106kPa
Temperature
0°C ~ 40°C
Relative humidity
10% ~ 90%
Antiseismic performance
Capable of resisting 7 ~ 9 Richter scale earthquake.
7-11
Technical Specifications
7.9 Environment Requirement
The following international standards are taken as the reference for framing the
environment requirements.
GF 014-95:
Environment conditions for the communication equipment room;
ETS 300 019-1-3: Class 3.2 Partly temperature-controlled locations;
NEBS GR-63-CORE: Network Equipment-Building System (NEBS) Requirement:
Physical Protection.
7.9.1 Environment for Storage
1. Climate
Table 7-14 Climate requirement
Item
Range
Altitude
5000m
Air pressure
70 ~ 106kPa
Temperature
-40°C ~ +70°C
Temperature change rate
1°C/min
Relative humidity
10% ~ 100%
Solar radiation
= 1120W/s²
Heat radiation
= 600W/s²
Air speed
= 30m/s²
2. Biological environment
Avoid multiplication of microbe, such as eumycete and mycete.
Avoid the rodent, e.g., mice.
3. Air cleanliness
No explosive, electric-conductive, magnetic-conductive or corrosive duct.
The density of the mechanical active substances complies with the requirements
listed in Table 7-15.
Table 7-15 Density requirements for mechanical active substances
Mechanical active
Content
substance
Suspending dust
= 5.00 mg/m³
7-12

 

 

 

 

 

 

 