1-62  HEATING AIR CONDITIONING

1-A

BLOWER MOTOR WOULD NOT ROTATE TOTALLY

(Refer to "WIRING HARNESS TERMINAL POSITIONS" in this section.)

Replace

YES

Is heater fuse (20A) OK?

Is heater relay OK?

YES

Is resistor OK?

YES

Is fan control knob (Fan switch) OK?

YES

YES

Check to see if battery voltage is present at chassis

side connector terminal No.

A

 - 

1

 (No.

A

 - 

2

; RHD)

Turn the ignition switch "ON" (Engine is running)

Fan control knob (Fan switch) "ON"

Is blower motor OK?

YES

Poor ground or open circuit either between chassis
side connector terminal No.

A

 - 

2

 (No.

A

 - 

1

; RHD)

and No.

B

 - 

6

 or No.

D

 - 

12

 and body ground

NO

Replace

NO

Replace

NO

NO

Replace control lever assembly

Replace

NO

NO

Open circuit between heater
fuse (20A) and No.

A

 - 

1

 (No.

A

2

; RHD)

HEATING AIR CONDITIONING  1-63

1-B

BLOWER MOTOR DOES NOT ROTATE IN CERTAIN POSITION

(Refer to "WIRING HARNESS TERMINAL POSITIONS" in this section.)

A

1: (Low)

Blower motor does not

B

2: (Medium Low) Position

run at

C

3: (Medium Hi)

D

4: (High)

* Checking is performed only when in the malfunction

mode.

Is resistor OK?

YES

Is fan control knob (Fan switch) OK?

YES

A

 Condition:

Open circuit between chassis side connector terminal

No.

B

 - 

22

 or No.

D

 - 

15

B

 Condition :

Open circuit between chassis side connector terminal

No.

B

 - 

3

 or No.

D

 - 

13

C

 Condition:

Open circuit between chassis side connector terminal

No.

B

 - 

5

 or No.

D

 - 

14

D

 Condition:

Open circuit between chassis side connector terminal

No. 

B

 - 

4

 or No.

D

 - 

10

Replace

NO

NO

Replace control lever assembly

1-64  HEATING AIR CONDITIONING

1-C

BLOWER MOTOR DOES NOT STOP AT "OFF" POSITION

(Refer to "WIRING HARNESS TERMINAL POSITIONS" in this section.)

Is fan control knob (Fan switch) OK?

YES

Short circuit between chassis side connector terminal

No. 

A

 - 

2

 (No.

A

 - 

1

; RHD) and No.

B

 - 

6

(or)

No.

B

 - 

4

 or No.

D

 - 

10

(or)

No.

B

 - 

5

 or No.

D

 - 

14

(or)

No.

B

 - 

3

 or No.

D

 - 

13

(or)

No.

B

 - 

22

 or No.

D

 - 

15

NO

Replace control lever assembly

HEATING AIR CONDITIONING  1-65

2-A

MAGNETIC CLUTCH WOULD NOT ENGAGE

(Refer to "WIRING HARNESS TERMINAL POSITIONS" in this section.)

Magnetic clutch deffective

NO

Are A/C (10A) and heater (20A) fuses OK?

Stop the engine

YES

Are heater and thermo switch relays OK?

YES

Is pressure switch (Dual pressure switch) OK?

YES

YES

Check the A/C related harness and repair it as necessary

Is thermo switch OK?

Are A/C switch and fan control knob (Fan switch)

YES

Replace

NO

Replace

NO

NO

Switch defective or insufficient
refrigerant

Replace

NO

Check to see if continuity between chassis side

connector terminal 

D

 - 

12

and ground

Check to see if battery voltage is present at

magnetic clutch chassis side connector terminal

Turn the ignition switch "ON" (Engine is running)

A/C switch and fan switch "ON"

YES

YES

Replace

NO

Poor ground or open circuit

NO

 

 

 

 

 

 

 