2.2.7.48 DTC P0685 

1. DTC 

description: 

DTC P0685  Main Relay Malfunction 

Main relay is used to provide power to fuel injectors and oxygen sensors and other components. 
Battery provides power to main relay terminal No.86. ECM controls main relay ground through 
ECM harness connector EM01 terminal No.62. ECM has a detection circuit. By monitoring the 
feedback voltage, ECM determines whether the control circuit is open, short to ground or short to 
power supply. 

2.  Conditions For Setting DTC and The Fault Location: 

DTC 
Code 

DTC Detection 
Strategy 

Conditions For Setting The DTC 
(Control Strategy) 

Fault Locations 

P0685 

Main Relay 
Malfunction 

The main relay control circuit does 
not match ECM expected status. 

1. Main 

Relay 

2.  Main Relay Circuit

3. ECM 

3. Circuit 

sketch 

主继电器ER09

蓄电池

点火开关

EF22

EF40

EF35

EF14

EF16

IF33

MAIN PWR

EM01 B+

68

67

5

EM01 IG+

EM01

MPR

44

EM01

GND

3

EM01

GND

2

EM01

30

87

85

86

5

6

NL02-0060c

 

4. Diagnostic 

Steps: 

1 Appearance 

Inspection 

Inspect main relay for signs of damage. 

 

Yes 

Replace main relay ,go to steps10 

No 

Ignition switch

Main relay ER09

Battery 

Engi

ne

 co

ntr

ol mo

dul

295

Inspect ECM harness connector EM01 terminal No.62. 

 

A.  Turn the ignition switch to OFF 

position. 

B. Dismantle of ECM harness 

connector EM01. 

C.  Measure voltage between ECM 

harness connector EM01 terminal 
No.44 and a reliable ground. 

Standard Voltage: 11-14V 

D. Measure resistance between 

ECM harness connector EM01 
terminal No.44 and a reliable 
ground. 

Rated resistance10KΩ or higher 

ECM线束连接器

EM01

1

2

4

5

3

81

63

44

25

6

62

43

24 23 22 21 20 19 18 17 16 15 14 13 12 11 10

9

8

7

26

42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27

45

46

61 60 59 58 57 56 55 54 53 52 51 50 49 48 47

64

65

66

80 79 78 77 76 75 74 73 72 71 70 69 68 67

NL02-0033c

Inspect whether according with the standard value? 

 

Inspect ECM harness connector EM01 terminals No.5, 2 and 3 

A.  Turn the ignition switch to OFF position. 

B.  Dismantle of ECM harness connector EM01. 

C.  Measure resistance between ECM harness connector EM01 terminal No.5 and a reliable 

ground. 

Rated resistance10KΩ or higher 

D.  Connect EM01 terminal NO.2 and 3 short to ground. 

E.  Measure voltage between EM01 terminal No.5 and a reliable ground. 

Standard Voltage: 11-14V 

Inspect whether according with the standard value? 

 

Inspect the ignition switch input signal. 

A  Turn the ignition switch to the ON position. 

B.  Measure voltage between ECM harness connector EM01 terminal No.68 and a reliable 

ground. 

Standard Voltage: 11-14V 

C.  Turn the ignition switch to the OFF position. 

No 

Go to step 5 

Yes 

No 

Repair the circuit from the battery to the 
EM01 terminal #62. Go to step 10. 

Yes 

ECMharness connectorEM01 

296

Whether voltage value is normal or not ? 

 

Inspect the voltage of the main relay terminals No.87 and 86. 

A.  Dismantle the main relay. 

B.  Measure voltage between the main relay terminal No.87 and 86 with a reliable ground. 

Standard Voltage: 11-14V 

C.  Measure resistance between the main relay terminal No.87 and 86 with a reliable ground. 

Rated resistance10KΩ or higher 

Inspect whether according with the standard value? 

 

Inspect main relay terminal No.30. 

 

A.  Install the main relay. 

B.  Connect ECM harness connector 

EM01 terminal No.2 and 3 to 
ground. 

C.  Measure voltage between main 

relay terminal No.3 and a reliable 
ground. 

Standard Voltage: 11-14V 

Check if it meet standard value ? 

ER03

85

86

87

30

30

87

86

85

ER05

30

87

86

85

ER06

30

87

87a

86

85

ER11

ER08

ER0

9

85

86

87

30

ER10

2

1

5

3

2

1

5

3

2

1

5

3

ER04

ER02

2

1

5

3

2

1

5

3

ER01

ER07

2

1

5

3

1

2

3

4

11

12

13

14

15

16

5

6

7

8

9

10

EF0

8

EF0

7

EF2

7

EF2

6

EF2

2

EF2

9

EF0

3

EF0

6

EF0

9

EF2

5

EF1

7

EF1

6

EF1

5

EF3

5

EF2

1

EF

1

4

EF

0

1

EF

0

2

EF

0

4

EF

1

0

EF

1

1

EF

1

8

EF

2

4

NL02-0045c

 

Inspect continuity between main relay and ECM harness connector. 

A.  Dismantle the main relay. 

B.  Measure resistance between main relay terminal No.30 and ECM harness connector EM01 

terminals No. 5. 

Standard Resistance: Less than 1 Ω 

Check if it meet standard value ? 

No 

Replace the main relay. Go to step 10. 

Yes 

No 

Repair the circuits from the battery to the main 
relay terminals #86 and #87. Go to step 10. 

Yes 

No 

Repair the circuit from the battery to 
the EM01 terminal #3. Go to step 10. 

Yes 

Go to step 8 

297

 

Inspect the ECM Power Supply Circuits. 

Refer to 2.2.7.43 DTC P0562 P0563. 

Inspect whether the ECM power supply circuit and ground circuit are normal. 

 

9 Replace 

ECM 

See 2.2.8.1 Replacement of Engine Control Module. 

 

10 

Use fault diagnosis tester to confirm if DTC is stored again . 

A.  Connect fault diagnosis tester to the data link connector. 

B.  Rotated ignition switch to ON position 

C.  Clear DTC code. 

D.  Start and run the engine at idle speed to warm up the engine for at least 5 min. 

E.  Road test the vehicle for at least 10min. 

F.  Read control system DTC code again to confirm that the system has no DTC code output. 

 

11 Troubleshooting 

No 

Refer to 2.2.7.3 Intermittent Fault 
Inspection for intermittent fault. 

Yes 

Next 

No 

Repair ECM Power Supply Circuits. 

Yes 

No 

Repair the circuits between main relay and 
terminals #6 and #22 of the EM01. Go to step 10. 

Yes 

298

 

 

 

 

 

 

 