5 Electrical installation ELECTRICAL INSTALLATION 2-163 43. CONNECTOR SOCKETS FA, DIAGNOSTIC CONNECTOR, ALARM CONNECTOR DIAGNOSTIC CONNECTOR (A021) Pin No. Wire No. Colour Designation 1 1229 red Supply for DAVIE 2 9107 white Earth 3 3425 blue ABS/ASC-D 4 4788 black ASL-G 5 4697 black ECAS remote control, E-gas 3, ECS-DC, 6 4732 black ECAS 2 8 3064 blue Connector 378, pin 5. 9 4047 black CTE-2 10 3065 blue Connector 378, pin 4. 11 4883 black ZF Intarder 12 3470 blue AGS 14 3037 blue D1LC / D3LC Compact auxiliary heating 24V CONNECTOR (A043) of the 24V connector (A034) is Pin 2 is connected to earth. ABS CONNECTOR (A004) of the ABS connector (A004) is Pin 2 is connected directly to the supply Pins 3 + 4 are both connected to earth. Pin 5 is connected to the CWS-2 unit (D583) 10 ǹ 9711 |