TEST ACTION APPLICABILITY 3 Turn the ignition off to the lock position. t Switch harness connector. Note: Check connectors - Clean/repair as necessary. t Downshift Sense circuit. Is the resistance below 5.0 ohms? All Yes → Repair the AutoStickt Downshift Sense circuit for a short to ground. No → Go To 4 4 Turn the ignition off to the lock position. t Switch harness connector. Note: Check connectors - Clean/repair as necessary. t Upshift Sense circuit. Is the resistance below 5.0 ohms? All Yes → Repair the AutoStickt Upshift Sense circuit for a short to ground. Perform 40/41TE (NGC) TRANSMISSION VERIFICATION No → Go To 5 5 Ignition on, engine not running. t display the AutoStickt Switch status. Shift into AutoStick t. Push the shift lever to the right several times to actuate the AutoStick t Upshift Switch and then to the left several times to actuate the AutoStick t Downshift Switch. Do both AutoStick t Upshift and Downshift Switch states toggle? All Yes → Test Complete. No → Replace the Powertrain Control Module per the Service Informa- tion. WITH THE DRBIII t PERFORM QUICK LEARN AND REPROGRAM PINION FACTOR. 128 TRANSMISSION - NGC P0952-AUTOSTICK INPUT CIRCUIT LOW — Continued |