Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual - part 225

 

  Index      Chrysler     Chrysler Sebring, Stratus sedan, Sebring Convertible - service repair manual 2001-2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  223  224  225  226   ..

 

 

Chrysler Sebring, Stratus sedan, Sebring Convertible. Manual - part 225

 

 

Symptom List:

P1603-PCM INTERNAL DUAL-PORT RAM COMMUNICATION
P1604-PCM INTERNAL DUAL-PORT RAM READ/WRITE INTEG-
RITY FAILURE
P1607-PCM INTERNAL SHUTDOWN TIMER RATIONALITY

Test Note:

All symptoms listed above are diagnosed using the same tests.

The title for the tests will be P1603-PCM INTERNAL DUAL-
PORT RAM COMMUNICATION.

When Monitored and Set Condition:

P1607-PCM INTERNAL SHUTDOWN TIMER RATIONALITY

When Monitored:

During cold start.

Set Condition:

Compares shut down time to coolant temperature.

POSSIBLE CAUSES

FUSED IGNITION SWITCH OUTPUT (OFF-RUN-START)

PCM INTERNAL FAULURE

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the PCM harness connector.
CAUTION: DO NOT PROBE THE PCM HARNESS CONNECTORS. PROBING
THE PCM HARNESS CONNECTORS WILL DAMAGE THE PCM TERMI-
NALS RESULTING IN POOR TERMINAL TO PIN CONNECTION. INSTALL
MILLER SPECIAL TOOL #8815 TO PERFORM DIAGNOSIS.
Turn the ignition to run.
Using a 12-volt test light connected to ground, probe the Fused Ignition Switch
Output (Off-Run-Start) cavity C1-12 circuit at the appropriate terminal of the special
tool #8815.
NOTE: If the test light illuminates, wiggle the wiring harness to ensure that
the problem is not an intermittent wiring problem.
Does the test light illuminate brightly?

All

Yes

→ Replace the Powertrain Control Module in accordance with the

Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.

No

→ Check all related fuses. Repair the Fused Ignition Switch Output

circuit.
Perform POWERTRAIN VERIFICATION TEST VER - 1.

277

DRIVEABILITY - NGC

Symptom List:

P1696-EEPROM MEMORY WRITE DENIED/INVALID
P1697-EMR (SRI) MILEAGE NOT STORED

Test Note:

All symptoms listed above are diagnosed using the same tests.

The title for the tests will be P1696-EEPROM MEMORY
WRITE DENIED/INVALID.

When Monitored and Set Condition:

P1696-EEPROM MEMORY WRITE DENIED/INVALID

When Monitored:

Ignition key on continuous.

Set Condition:

An attempt to program/write to the internal EEPROM failed. Also checks

at powerdown.

P1697-EMR (SRI) MILEAGE NOT STORED

When Monitored:

Ignition key on continuous.

Set Condition:

An attempt to program/write to the internal EEPROM failed. Also checks

at powerdown.

POSSIBLE CAUSES

DRB DISPLAYS WRITE FAILURE

DRB DISPLAYS WRITE REFUSED 2ND TIME

DRB DISPLAYS SRI MILEAGE INVALID

COMPARE SRI MILEAGE WITH ODOMETER

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, perform the SRI Memory Test.

Does the DRBIII

t display Write Failure?

All

Yes

→ Replace and program the Powertrain Control Module in accor-

dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.

No

→ Go To 2

2

With the DRBIII

t, perform the SRI Memory Test.

Does the DRBIII

t display Write Refused?

All

Yes

→ Go To 3

No

→ Go To 4

278

DRIVEABILITY - NGC

TEST

ACTION

APPLICABILITY

3

With the DRBIII

t, perform the SRI Memory Test a second time.

NOTE: Retest the SRI Memory two more times.
Does the DRBIII

t display Write Refused again?

All

Yes

→ Replace and program the Powertrain Control Module in accor-

dance with the Service Information.
Perform POWERTRAIN VERIFICATION TEST VER - 1.

No

→ Test Complete.

4

With the DRBIII

t, perform the SRI Memory Test.

Does the DRBIII

t display SRI Mileage Invalid?

All

Yes

→ Update the mileage and retest the SRI Memory.

Perform POWERTRAIN VERIFICATION TEST VER - 1.

No

→ Go To 5

5

Compare the SRI Mileage stored with the Instrument Panel Odometer.
Is the mileage within the specified range displayed on the DRBIII

t?

All

Yes

→ Test Complete.

No

→ Update the mileage and retest the SRI Memory.

Perform POWERTRAIN VERIFICATION TEST VER - 1.

279

DRIVEABILITY - NGC

P1696-EEPROM MEMORY WRITE DENIED/INVALID —

Continued

Symptom:

P2074-MANIFOLD PRESSURE/THROTTLE POSITION CORRELA-
TION - HIGH FLOW/VACUUM LEAK

When Monitored and Set Condition:

P2074-MANIFOLD PRESSURE/THROTTLE POSITION CORRELATION - HIGH
FLOW/VACUUM LEAK

When Monitored:

Engine Running, during all drive modes.

Set Condition:

If vacuum drops below 1.5 Hg with engine RPM greater than 2000 RPM

at closed throttle.

POSSIBLE CAUSES

GOOD TRIP EQUAL TO ZERO

VACUUM LEAK

HIGH RESISTANCE IN MAP (K6) 5 VOLT SUPPLY CIRCUIT

RESISTANCE TO GROUND IN MAP (K6) 5 VOLT SUPPLY CIRCUIT

MAP SENSOR

HIGH RESISTANCE IN (K1) MAP SIGNAL CIRCUIT

RESISTANCE TO GROUND IN (K1) MAP SIGNAL CIRCUIT

HIGH RESISTANCE IN (K4) MAP GROUND CIRCUIT

PCM

TP SENSOR OPERATION

HIGH RESISTANCE IN TP SENSOR (K6) 5 VOLT SUPPLY CIRCUIT

RESISTANCE TO GROUND IN TP SENSOR (K6) 5 VOLT SUPPLY CIRCUIT

TP SENSOR

HIGH RESISTANCE IN (K22) TP SIGNAL CIRCUIT

RESISTANCE TO GROUND IN (K22) TP SENSOR SIGNAL CIRCUIT

HIGH RESISTANCE IN TP (K4) SENSOR GROUND CIRCUIT

PCM

280

DRIVEABILITY - NGC

 

 

 

 

 

 

 

Content   ..  223  224  225  226   ..