Index Chrysler Chrysler Sebring, Stratus sedan, Sebring Convertible - service repair manual 2001-2007 year
|
|
Symptom: P1115-GENERAL TEMP SENSOR PERFORMANCE When Monitored and Set Condition: P1115-GENERAL TEMP SENSOR PERFORMANCE When Monitored: Engine off time is greater than 480 minutes. Ambient temperature is greater than -23°C (-10°F). Set Condition: After a calibrated amount of cool down time, the PCM compares the ECT Sensor, IAT Sensor and the Ambient Air Temperature Sensor values. If the (AAT and IAT), POSSIBLE CAUSES GOOD TRIP EQUAL TO ZERO OTHER POSSIBLE CAUSES SIGNAL CIRCUIT SHORTED TO BATTERY VOLTAGE TEMPERATURE SENSOR VOLTAGE BELOW 1.0 VOLT SIGNAL CIRCUIT OPEN SENSOR GROUND CIRCUIT OPEN SIGNAL CIRCUIT SHORTED TO GROUND SIGNAL CIRCUIT SHORTED TO SENSOR GROUND PCM LOW PCM HIGH TEST ACTION APPLICABILITY 1 NOTE: NOTE:Due to the fact that the PCM compares the IAT, AAT and ECT t, read DTCs and record the related Freeze Frame data. Is the Good Trip displayed and equal to zero? All Yes → Go To 2 No → Refer to the INTERMITTENT CONDITION symptom in the Driveability category. 269 DRIVEABILITY - NGC |