Symptom:

DRIVER

DOOR

CENTRAL

LOCK

(ARM)/UNLOCK

(DISARM)

SWITCH FAILURE

When Monitored and Set Condition:

DRIVER DOOR CENTRAL LOCK (ARM)/UNLOCK (DISARM) SWITCH FAILURE

When Monitored:

Continuously

Set Condition:

If the BCM detect a signal on the Driver Cylinder Lock Switch Mux circuit

for over 10 seconds this code will set and will ignore the offending input until it is corrected.

POSSIBLE CAUSES

BINDING DRIVER CYLINDER LOCK SWITCH

DRIVER CYLINDER LOCK SWITCH SHORTED TO VOLTAGE

DRIVER CYLINDER LOCK SWITCH MUX CIRCUIT SHORTED TO VOLTAGE

WIRING HARNESS INTERMITTENT DEFECT

BODY CONTROL MODULE - DRIVER CYLINDER LOCK SWITCH FAILURE

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, erase DTC’s.

Insert the key in the Driver Cylinder Lock Switch and rotate the key to the lock and
unlock positions several times.
With the DRBIII

t, read DTC’s.

Did this DTC reset?

All

Yes

→ Go To 2

No

→ Go To 6

2

Insert the key in the Driver Cylinder Lock Switch and rotate the key to the lock and
unlock positions.
Does the key bind in any position?

All

Yes

→ Repair or replace the Driver Cylinder Lock Switch as necessary.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

3

Disconnect the Driver Cylinder Lock Switch harness connector.
Turn the ignition on.
With the DRBIII, enter

9Body Computer9 then 9Sensors9 and observe the Dr Door

Disarm SW voltage
Is there any voltage present?

All

Yes

→ Go To 4

No

→ Replace the Driver Cylinder Lock Switch.

Perform BODY VERIFICATION TEST - VER 1.

397

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

Turn the ignition off.
Disconnect the Driver Cylinder Lock Switch harness connector.
Disconnect the BCM

9C49 harness connector.

Turn the ignition on.
Measure the voltage of the Driver Cylinder Lock Switch Mux circuit.
Is there any voltage present?

All

Yes

→ Repair the Driver Cylinder Lock Switch Mux circuit for a short to

voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

If there are no possible causes remaining, view repair.

All

Repair

Replace the Body Control Module in accordance with the Service
Information.
Perform BODY VERIFICATION TEST - VER 1.

6

Turn the ignition off.
NOTE: Using the wiring diagram/schematic as a guide, inspect the wiring
and connectors.
Were any problems found?

All

Yes

→ Repair wiring harness or connectors as necessary.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Test Complete.

398

POWER DOOR LOCKS/RKE

DRIVER DOOR CENTRAL LOCK (ARM)/UNLOCK (DISARM) SWITCH
FAILURE —

Continued

Symptom:

RKE FOB BATTERY LOW

When Monitored and Set Condition:

RKE FOB BATTERY LOW

When Monitored:

Anytime an RKE message is received from the transmitter.

Set Condition:

RKE receiver detects an RKE FOB battery low signal (less than 3 volts)

for 5 consecutive button presses.

POSSIBLE CAUSES

BATTERIES LOW

TRANSMITTER - LOW VOLTAGE OUTPUT

TEST

ACTION

APPLICABILITY

1

To determine which transmitter set the code, press any button on each transmitter.
If a chime in the BCM is heard when a button is pressed, that is the problem
transmitter.
Test the voltage of each battery in the problem transmitter..
Is the voltage at or above 3.0 in each battery?

All

Yes

→ Replace the RKE Transmitter.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the batteries.

Perform BODY VERIFICATION TEST - VER 1.

399

POWER DOOR LOCKS/RKE

Symptom:

RKE PROGRAM MODE ENTERED WITHOUT PROGRAM REQUEST

When Monitored and Set Condition:

RKE PROGRAM MODE ENTERED WITHOUT PROGRAM REQUEST

When Monitored:

Continuously.

Set Condition:

The BCM receives an indication from the RKE module that it has entered

program mode without the BCM requesting so.

POSSIBLE CAUSES

REMOTE KEYLESS ENTRY MODULE

RKE PROGRAM MODE ENTERED WITHOUT PROGRAM REQUEST

TEST

ACTION

APPLICABILITY

1

Note: This DTC will only set if the BCM receives an indication from the RKE
module that it has entered program mode without the BCM requesting so.
Replace the Remote Keyless Entry Module and program a transmitter..
With the DRBIII, clear DTCs.
Operate the Door Locks several times with the RKE transmitter.
With the DRBIII

t, read DTC’s.

Did this DTC reset?

All

Yes

→ Replace the Body Control Module in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ If the replaced module was a test unit only, replace the RKE

module. Program all transmitters used with this vehicle.
Perform BODY VERIFICATION TEST - VER 1.

400

POWER DOOR LOCKS/RKE

 

 

 

 

 

 

 