TEST
ACTION
APPLICABILITY
4
Turn the ignition off.
Disconnect the Instrument Cluster harness connector.
NOTE: Ensure all lights are turned off.
Using a 12-volt test light connected to 12-volts, probe each ground circuit.
Is the test light illuminated for each circuit?
All
Yes
→ Go To 5
No
→ Repair the Ground circuit(s) for an open. Refer to the wiring
diagrams located in the Service Information.
Perform BODY VERIFICATION TEST - VER 1.
5
Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the Instrument Cluster harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
With the DRBIII
t, select Pep Module Tools.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
(MIC) circuit in the Instrument Cluster connector (cav 2).
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?
All
Yes
→ Replace the Instrument Cluster in accordance with the service
information.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 6
6
Turn the ignition off.
Disconnect the Instrument Cluster harness connector.
Disconnect the BCM C2 harness connector.
Measure the resistance of the PCI bus circuit between the Instrument Cluster
connector and the BCM C2 connector.
Is the resistance below 5.0 ohms?
All
Yes
→ Replace the Body Control Module in accordance with the service
information.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Repair the PCI Bus circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
209
COMMUNICATION
*NO RESPONSE FROM INSTRUMENT CLUSTER —
Continued