Symptom: FUEL SENSOR 2 SHORT - BCM When Monitored and Set Condition: FUEL SENSOR 2 SHORT - BCM When Monitored: When the BCM is powered up. Set Condition: This DTC will set when the BCM detects the Fuel Level Sensor 2 circuit resistance is less than 25 ohms for 10 seconds. POSSIBLE CAUSES FUEL LEVEL SENSOR FUEL LEVEL SENSE 2 CIRCUIT SHORT TO GROUND BODY CONTROL MODULE TEST ACTION APPLICABILITY 1 Turn the ignition off. t, read DTCs. Does the DRBIII t display 9Fuel Sensor 2 Open9? All Yes → Replace the Fuel Level Sensor in accordance with the Service Information. No → Go To 2 2 Turn the ignition off. All Yes → Repair the Fuel Level Sense 2 circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1. No → Replace and program the BCM in accordance with the Service Information. 717 INSTRUMENT CLUSTER |