Symptom: EVIC SWITCH INPUT STUCK When Monitored and Set Condition: EVIC SWITCH INPUT STUCK When Monitored: The MIC power-up diagnostics will test the EVIC Button A/D port for either an open circuit, short to power or ground, or a stuck button exists. Set Condition: This DTC will set when the Instrument Cluster detects the EVIC Mux Signal circuit is active for 30 seconds. POSSIBLE CAUSES DTC PRESENT INSTRUMENT PANEL SWITCH POD TEST ACTION APPLICABILITY 1 NOTE: Diagnose and repair any EVIC Switch Input Short or Open DTC’s t, record and erase DTC’s. Cycle the ignition switch from ON to OFF to ON. t, read DTC’s. Wait 30 seconds. t display EVIC SWITCH INPUT STUCK? All Yes → Replace the Instrument Panel Switch Pod in accordance with the Service Information. No → The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the 713 INSTRUMENT CLUSTER |