Volkswagen Golf / Golf GTI / Jetta. Manual - part 900

 

  Index      Volkswagen     Volkswagen Golf / Golf GTI / Jetta - service repair manual 1999-2005 year

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  898  899  900  901   ..

 

 

Volkswagen Golf / Golf GTI / Jetta. Manual - part 900

 

 

01-376

 

  

  

-  A button must be pressed once on each of the 

radio wave keys to be "learned" (in example 
above, 3 keys). 

  

  

-  Switch off ignition and remove ignition key.  

  

  

-  Perform functional check (e.g. 3) of radio wave 

keys. 

  

   Note:  

  

  

 All 3 keys (see example) can be "learned" in 

one matching sequence. 

  

  

 15 seconds must not be exceeded when 

matching all ignition keys (pressing a button).  

  

  

 A successful adaptation can be determined via 

Read Measuring Value Block, function 08, 
display group number 013, 

 

Page 01-277

 . 

When operation the radio wave unit both of first 
measurement values must have the status OK. 
Simultaneously the last measurement value will 
show the positional number of the key (i.e. first, 
second, third, fourth key).
 

  

  

 If the remote control button is operated several 

times the third display -no measured value- 
changes to "OK".
 

Central locking system (vehicles without power windows), On Board Diagnostic ...

13/2/2005

01-377

 

  

  

The matching of ignition keys is automatically 
terminated when:  

  

  

 Number of keys to be matched is reached.  

  

  

 A button of one of the keys to be "learned" is 

pressed frequently. 

  

  

 Permissible matching period of 15 seconds is 

exceeded (malfunction is stored). 

  

  

-  Select function 02 "Check DTC memory". If 

there is no malfunction stored, the matching of 
the keys has been successfully completed. 

  

  

-  Press buttons -0- and -6- to end the output.  

Rapid data transfer 

Q

06 End output

     Indicated on display:  

-  Confirm entry with the -Q- button. 

Rapid data transfer 

HELP

Enter address word XX

     Indicated on display:  

-  Switch off ignition. 

-  Disconnect connector to V.A.G 1551 scan tool. 

Central locking system (vehicles without power windows), On Board Diagnostic ...

13/2/2005

01-378

 
The various functions listed in the table can be called up and adapted by selecting the 
channel numbers 03 to 10. 

Radio wave remote control functional variants

 

Channel 
number 
 

Significance  

Measured 

value  

03  

Auto lock/unlock: Vehicles will be locked when a speed of 

15 km/h is reached  

on=1  

off= 0  

04  

Auto lock/unlock: Vehicles will be unlocked when the 

ignition key is withdrawn from the ignition lock  

on=1  

off= 0  

05  

IM switch-off: Interior monitoring is activated or 

deactivated by operating central locking closed twice  

on=1  

off= 0  

06  

Horn sounds when unlocking: Confirmation signal when 

unlocking

1)

  

on=1  

off= 0  

07  

Horn sounds when locking: Confirmation signal when 

locking

1)

  

on=1  

off= 0  

08  

Turn signals flash when unlocking: Unlocking is 

confirmed by turn signals flashing twice  

on=1  

off= 0  

09  

Horn sounds when locking: Locking is confirmed by turn 

signals flashing once  

on=1  

off= 0  

10  

Setting for alarm horn: Programming the horn operation 

when the alarm is triggered appropriate to the legislation 

of the countries  

1= Rest of 

Europe  

2= Germany  

3= Great 

Britain  

1)

 No longer allowed according to German legislation. 

 

Central locking system (vehicles without power windows), On Board Diagnostic ...

13/2/2005

01-379

 

  

  

The matching shown here is only an 
example.  

Rapid data transfer 

HELP

Select function XX

     Indicated on display:  

-  Press buttons -1- and -0- (10 

selects function "Adaptation"). 

Rapid data transfer 

Q

10 - Adaptation

     Indicated on display:  

-  Confirm entry with the -Q- button. 

Adaptation 

Enter channel number XX

     Indicated on display:  

-  Press buttons -0- and -8- 

(channel number 08 switches the 
turn signals on or off when 
unlocking). 

Channel 8 Adaptation 1 

Unlock Flashing on <-1 3->

     Indicated on display:  

-  Press 

button. 

Channel 8.........Adaptation 1 

Enter adaptation value XXXXX

     Indicated on display:  

-  Press 

button. 

-  Press button -0- five times (e.g. 

00000). 

Channel 8.........Adaptation 0 

Q

Enter adaptation value 00000

     Indicated on display:  

-  Confirm entry with the -Q- button. 

Central locking system (vehicles without power windows), On Board Diagnostic ...

13/2/2005

 

 

 

 

 

 

 

Content   ..  898  899  900  901   ..