01-159
Work step 7: Oxygen Sensor Rapid data transfer HELP Select function XX Indicated on display: - Press buttons -0- and -4- for function "Initiate basic setting" Basic setting Input display group number XXX Indicated on display: - Press buttons -0-, -3- and -4- for "Display group number 34" and System in basic setting 34
1 2 3 4 Indicated on display: (1...4 display zones) - Depress brake pedal and hold. - Depress accelerator down to wide open throttle position. Engine speed will be increased by Motronic Engine Control Module - Depress brake pedal and accelerator down until display in Readiness code |