Content .. 1478 1479 1480 1481 ..
HO2 Sensor (for Bank 1 Sensor 2) MONITOR RESULT INFORMATION - HO2 SENSOR HO2 Sensor (for Bank 2 Sensor 2) MONITOR RESULT INFORMATION - HO2 SENSOR Catalyst (for Bank 1) MONITOR RESULT INFORMATION - CATALYST (FOR BANK 1) Catalyst (for Bank 2) MONITOR RESULT INFORMATION - CATALYST (FOR BANK 2) EVAP MONITOR RESULT INFORMATION - EVAP Monitor ID Test ID Scaling Unit Description $02 $07 Multiply by 0.001 V Minimum sensor voltage $02 $08 Multiply by 0.001 V Maximum sensor voltage $02 $8D Multiply by 0.001 Seconds Duration that sensor voltage drops to 0.2 V during fuel $02 $8F Multiply by 0.0003 g Maximum oxygen storage capacity Monitor ID Test ID Scaling Unit Description $06 $07 Multiply by 0.001 V Minimum sensor voltage $06 $08 Multiply by 0.001 V Maximum sensor voltage $06 $8D Multiply by 0.001 Seconds Duration that sensor voltage drops to 0.2 V during fuel $06 $8F Multiply by 0.0003 g Maximum oxygen storage capacity Monitor ID Test ID Scaling Unit Description $21 $A9 Multiply by 0.0003 No dimension Oxygen storage capacity of catalyst Monitor ID Test ID Scaling Unit Description $22 $A9 Multiply by 0.0003 No dimension Oxygen storage capacity of catalyst Monitor ID Test ID Scaling Unit Description $3D $C9 Multiply by 0.001 kPa Test value for small leak (P0456) $3D $CA Multiply by 0.001 kPa Test value for gross leak (P0455) $3D $CB Multiply by 0.001 kPa Test value for leak detection pump stuck OFF (P2401) $3D $CD Multiply by 0.001 kPa Test value for leak detection pump stuck ON (P2402)
2009 Toyota Tundra 2009 ENGINE PERFORMANCE Engine Control System (3UR-FBE) - Tundra
|