Subaru Legacy IV (2008 year). Manual - part 1091

 

  Index      Subaru     Subaru Legacy IV - service repair manual 2008 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1089  1090  1091  1092   ..

 

 

Subaru Legacy IV (2008 year). Manual - part 1091

 

 

IDI-5

Combination Meter System

INSTRUMENTATION/DRIVER INFO

2. Combination Meter System

A: WIRING DIAGRAM

1. COMBINATION METER

<Ref. to WI-166, WIRING DIAGRAM, Combination Meter System.>

B: INSPECTION

1. SELF-DIAGNOSIS

The self-diagnosis (checking of each meter, warning light, indicator, illumination, LCD, buzzer sound) of com-
bination meter can be performed in the following procedure.

NOTE:
Perform the steps described in 2) through 4) within 10 seconds.
1) Within 3 seconds after turning the ignition switch to ON, set the lighting switch to tail light or headlight po-
sition.
2) Press the odo/trip meter knob three times.
3) Turn the lighting switch to OFF, and press the odo/trip meter knob three times.
4) Set the lighting switch to tail light or headlight position again, and press the odo/trip meter knob three
times.

NOTE:
• When pressing the odo/trip meter knob four times, the display changes to DTC display mode. <Ref. to IDI-
18, DTC DISPLAY MODE, INSPECTION, Combination Meter System.>
• When the self-diagnosis function operates, the warning light, indicator, and LCD display checks are per-
formed. After this, operation checks are performed in the order of meter, illumination, and buzzer for each
press of the odo/trip meter knob button. <Ref. to IDI-6, LIST OF SELF-DIAGNOSIS MODE OPERATION, IN-
SPECTION, Combination Meter System.> Turn the ignition switch to OFF to cancel the self-diagnosis func-
tion.
• When the engine starts during diagnosis, the self-diagnosis function is not cancelled, however, once the
vehicle starts driving, the self-diagnosis function is deactivated automatically for safety.

IDI-6

Combination Meter System

INSTRUMENTATION/DRIVER INFO

2. LIST OF SELF-DIAGNOSIS MODE OPERATION

Normal meter

Speedometer, 
tachometer, fuel 
gauge, engine 
coolant tempera-
ture gauge

Microcomputer 
running type 
warning light, 
indicator light

AT select lever 
position indicator 
light

Odo/Trip indica-
tor

SPORT shift 
indicator

Illumination 
(indicator needle, 
plate, ring, LCD)

Buzzer 
(SPORT shift 
buzzer, VDC 
buzzer)

Step 0. Processing to self-diagnosis function

Operating initial 
operation

Initial illuminat-
ing

Normal

Normal

Initial illuminat-
ing

Initial illuminating

Not beep.

Step 1-1. Check each indication after initial operation

Repeat the 
sweep operation 
(After holding on 
lowest position for 
one second, 
reaches to high-
est position within 
5 seconds, and 
after holding on 
highest position 
for one second, 
reaches to low-
est position within 
5 seconds).

Light ON

With the highest 
brightness, illumi-
nate the position 
sequentially at a 
cycle of 1.5 sec-
onds.

Perform the 
segment check. 
For the illumina-
tion order, refer 
to the illumina-
tion order table.

Perform the 
segment check. 
For the illumi-
nation order, 
refer to the illu-
mination order 
table.

Light at the high-
est brightness.

Not beep.

Step 1-2. Press the trip knob (trip knob input is not accepted till the meter indicator needle reaches the highest position): sweep 
complete, AT select lever position indicator display is set

After completing 
sweep in step 1-
1, back to lowest 
position.

Light ON

Keep the position 
indicated when 
the trip knob is 
pressed.

Underbar “ _ ” is 
displayed.

“1” is displayed.

Light at the high-
est brightness.

Not beep.

Step 2-1. Press the trip knob, and hold it: Check each meter

All meters are 
moved simulta-
neously in every 
0.5 seconds from 
the lowest posi-
tion to highest 
position.
Speedometer/
Tachometer: 
Approx. 5 
degrees at every 
movement.
Engine coolant 
temperature /Fuel 
gauge: Moves 
approx. 2 
degrees at a time.

Light OFF

Keep the position 
indicated that set 
in step 1-2.

Display the cur-
rent meter 
directing angle 
on odometer.
Ex.) When the 
speedometer/
tachometer: 135 
degrees and 
engine coolant 
temperature 
gauge/fuel 
gauge: 54 
degrees, dis-
plays “135054”.

2”  is  dis-

played.

Light at the high-
est brightness.

Not beep.

Step 2-2. Release the trip knob: Specifying the meter directing position

Stop at directing 
position when the 
trip knob is 
released.

Light OFF

Keep the position 
indicated that set 
in step 1-2.

Display the cur-
rent meter 
directing angle 
on odometer.

“2” is displayed.

Light at the high-
est brightness.

Not beep.

Step 3-1. Press the trip knob, and hold it: Check illumination

IDI-7

Combination Meter System

INSTRUMENTATION/DRIVER INFO

• Illuminating order table

Keep the position 
that specified at 
step 2-2.

Light OFF

Varying from the 
highest bright-
ness (ILL6) to the 
lowest lumines-
cence (ILL1) 
every second. 
After reaching at 
ILL1, repeat it 
from ILL6.

Illumination 
brightness is 
displayed. 
(From ILL6 to 
ILL1)

3”  is  dis-

played.

Varying from the 
highest bright-
ness (ILL6) to the 
lowest lumines-
cence (ILL1) 
every second. 
After reaching at 
(ILL1), repeat it 
from (ILL6).

Not beep.

Step 3-2. Release the trip knob: Specifying the illumination brightness

Keep the position 
that specified at 
step 2-2.

Light OFF

Keep the bright-
ness at the time 
when the trip 
knob is released.

Displays the 
brightness level 
at the time when 
the trip knob 
was released.

“3” is displayed.

Keep the bright-
ness at the time 
when the trip 
knob is released.

Not beep.

Step 4-1. Press the trip knob: Check the beeping of SPORT shift buzzer (For AT model)

All meter indica-
tor needle returns 
to lowest position.

Light OFF

Light at the high-
est brightness. 
Keep the position 
indicated that set 
in step 1-2.

Illumination 
brightness is 
displayed.

 

8” is dis-

played. Blinks 
with buzzer.

Light at the high-
est brightness.

SPORT shift 
buzzer beeps.

Step 4-2. Press the trip knob: Check the VDC indicator light (Model with VDC)

All meter indica-
tor needle returns 
to lowest position.

VDC warning 
light and VDC 
operation indi-
cator light blink.

Light at the high-
est brightness. 
Keep the position 
indicated that set 
in step 1-2.

Illumination 
brightness is 
displayed.

“4” is displayed.

Light at the high-
est brightness.

VDC buzzer 
beeps.

Step 5. Press the trip knob: Complete the self-diagnosis 1 cycle

All meter indicator needle returns to lowest position, and go back to step 1 after completion.

Illuminating 
order

1

2

3

4

5

6

7

8

9

10

11

Go back 

to 1 and 

repeat.

Trip  meter  A/B

AB

A

B

A

B

A

B

A

B

A

B

Odo/trip meter

8888.8

888888

00000

000000

1111.1

111111

22222

222222

3333.3

333333

44444

444444

5555.5

555555

66666

666666

7777.7

777777

88888

888888

9999.9

999999

SPORT shift 
indicator

8

1

2

3

4

5

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

AT select lever 
position indicator

P

P

R

R

R

N

N

N

D

D

D

Display time 
(sec.)

1

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

0.5

Speedometer, 
tachometer, fuel 
gauge, engine 
coolant tempera-
ture gauge

Microcomputer 
running type 
warning light, 
indicator light

AT select lever 
position indicator 
light

Odo/Trip indica-
tor

SPORT shift 
indicator

Illumination 
(indicator needle, 
plate, ring, LCD)

Buzzer 
(SPORT shift 
buzzer, VDC 
buzzer)

IDI-8

Combination Meter System

INSTRUMENTATION/DRIVER INFO

3. LIST OF SELF-DIAGNOSIS MODE OPERATION

Meter with multi-information display

Speedometer, tachome-
ter, fuel gauge, engine 
coolant temperature 
gauge, ECO gauge

Microcomputer 
running type 
warning light, 
indicator light

AT select lever 
position indica-
tor light

Multi-information dis-
play

Illumination 
(indicator needle, 
plate, ring, LCD)

Buzzer (SPORT 
shift buzzer, 
VDC buzzer, 
vehicle speed 
warning buzzer)

Step 0. Processing to self-diagnosis function

Operating initial opera-
tion

Initial illuminating Normal

TRIP: Normal
ODO: Normal

Initial illuminating

Not beep.

Step 1-1. Check each indication after initial operation

Repeat the sweep opera-
tion (After holding on 
lowest position for one 
second, reaches to high-
est position within 5 sec-
onds, and after holding 
on highest position for 
one second, reaches to 
lowest position within 5 
seconds).

Light ON

Perform the 
segment check. 
For the illumina-
tion order, refer 
to the table 1 of 
illumination 
order tables.

STEP 1 is displayed.
White illumination: 6 
seconds.
Yellow illumination: 6 
seconds.

Light at the highest 
brightness.

Not beep.

Step 1-2. Press the trip knob: sweep completes, AT select lever position indicator display is set

After quitting sweep in 
step 1-1, back to lowest 
position. (Until back to 
lowest position, ignore 
trip input.)

Light ON

Keep the posi-
tion indicated 
when the trip 
knob is pressed.

Keep the illumination 
color indicated when 
the trip knob is 
pressed.

Light at the highest 
brightness.

Not beep.

Step 2-1. Press the trip knob, and hold it: Check each meter

Perform the indicator 
needle check. For the 
illumination order, refer 
to the table 2 of illumina-
tion order tables.

Light OFF (Low 
fuel warning light 
follows the table 
2 of tables.)

For the illumina-
tion order, refer 
to the table 2 of 
illumination 
order tables.

STEP 2 is displayed.
White illumination: 
12.5 seconds.
Yellow illumination: 
12.5 seconds.

Light at the highest 
brightness.

Not beep.

Step 2-2. Release the trip knob: Specifying the meter directing position

Stop at directing posi-
tion when the trip knob is 
released. (Indicator nee-
dle stops moving after 
movement is completed.)

Light OFF

Keep the posi-
tion indicated 
when the trip 
knob is 
released.

Keep the illumination 
color at the time when 
the trip knob is 
released.

Light at the highest 
brightness.

Not beep.

Step 3-1. Press the trip knob, and hold it: Check illumination

Keep the position that 
specified at step 2-2.

Light OFF

Keep the posi-
tion that speci-
fied at step 2-2.

STEP 3 is displayed, 
then illumination 
brightness is dis-
played. 
(From ILL6 to ILL1)

Varying from the 
highest brightness 
(ILL6) to the lowest 
luminescence (ILL1) 
every second. After 
reaching at (ILL1), 
repeat it from (ILL6).

Not beep.

Step 3-2. Release the trip knob: Specifying the illumination brightness

Keep the position that 
specified at step 2-2.

Light OFF

Keep the posi-
tion that speci-
fied at step 2-2.

Keep the position indi-
cated when the trip 
knob is pressed.

Keep the brightness 
at the time when the 
trip knob is released.

Not beep.

Step 4-1. Press the trip knob: Check the beeping of multi buzzer

All meter indicator nee-
dle returns to lowest 
position.

Light OFF

P is displayed in 
white illumina-
tion.

STEP 3 WN BUZZER 
is displayed.
White illumination: 
1 second.
Yellow illumination: 
1 second.

Light at the highest 
brightness.

Buzzer beeps 
when multi infor-
mation display is 
yellow illumina-
tion.

 

 

 

 

 

 

 

Content   ..  1089  1090  1091  1092   ..