SsangYong Rexton. Manual - part 684

 

  Index      SsangYong     SsangYong Rexton - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  682  683  684  685   ..

 

 

SsangYong Rexton. Manual - part 684

 

 

SSANGYONG  Y200

9D-50  BODY ELECTRICAL

Trouble Shooting

Flow Chart – Mode Of Wiper Operation

Ground of “W” is “ ON” ?

1 of relay is “OFF” 2 of relay  is “ON”

(Motor is turning to counter-clockwise)

Ground of “W” is “ ON”?

Turn wiper switch ON

1 of relay is “ ON”,2 of relay is “OFF”

(Motor is turning to clockwise)

ON

YES

ON

YES

BODY ELECTRICAL  9D-51

SSANGYONG  Y200

Parking Mode

Parking is under operation of the clock wise.

Parking  is  under  operation  of  the  counter  clock
wise.

1 of relay is OFF, 2 of relay is OFF

(motor : stop), wate for 1 minute

1 of relay is ON, 2 of relay is OFF

(motor is turning to clock wise)

Ground of P is ON ?

Motor is operating to the clock wise wiper

switch is off or switch of intermittent is off

Ground of “W is “ON” ?

YES

1 of relay is OFF, 2 of relay is

ON motor : stop

NO

NO

YES

1 of relay is OFF, 2 of relay is OFF

(motor : stop), wate for 1 minute

1 of relay is OFF, 2 of relay is ON

(motor is turning to counter-clock wise)

Ground of P is ON ?

Motor is operating to the counterclock

wise wiper switch is off or switch of

intermittent is off

Ground of “W is “ON” ?

YES

1 of relay is OFF, 2 of relay is

OFF motor : stop

NO

NO

YES

SSANGYONG  Y200

9D-52  BODY ELECTRICAL

1 of relay is ON, 2 of relay is OFF

motor is turning to clockwise

Ground of “W” is ON ?

1 of relay is OFF, 2 of relay is “ON

Turn washer switch on

Is it passing time o.5 second

YES

Ground of “W” is ON ?

NO

YES

1 of relay is ON, 2 of relay is OFF

motor is turning to clockwise

YES

Ground of “W” is ON ?

YES

Parking : is operating under the

clockwise (motor : stop )

1 of relay is off, 2 of relay is off

(motor : stop)

NO

NO

NO

Operation Of Washer Mode

BODY ELECTRICAL  9D-53

SSANGYONG  Y200

Motor is operating : limit switch is ON

Ground of W is ON?

1 of relay is OFF, 2 of relay is OFF

(motor : stop)

YES

1 of relay is ON, 2 of relay is OFF

(motor : is turning clockwise)

Ground of P is ON ?

1 of relay is OFF, 2 of relay is OFF

(motor : stop)

NO

NO

Limit switch is ON

Wiper switch is ON, or Intermittent is

ON

1 of relay is OFF, 2 of relay is OFF

(motor : stop)

Operation of Limit Switch

YES

 

 

 

 

 

 

 