Nissan Quest E52. Manual - part 406

 

  Index      Nissan     Nissan Quest E52 (2011-2014 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  404  405  406  407   ..

 

 

Nissan Quest E52. Manual - part 406

 

 

DLK-338

< DTC/CIRCUIT DIAGNOSIS >

FUEL LID STATUS SWITCH

FUEL LID STATUS SWITCH

Component Function Check

INFOID:0000000009649280

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR” using CONSULT.

2.

Select “F LID SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Fuel filler lid status switch is OK.

NO

>> Refer to 

DLK-338, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009649281

1.

CHECK FUEL FILLER LID STATUS SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect fuel filler lid status switch connector.

3.

Check voltage between fuel filler lid status switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK FUEL FILLER LID STATUS SWITCH CIRCUIT

1.

Disconnect sliding door control unit LH connector.

2.

Check continuity between sliding door control unit LH harness connector and fuel filler lid status switch
harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit LH. Refer to 

DLK-500, "LH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK FUEL FILLER LID STATUS SWITCH GROUND CIRCUIT

Check continuity between fuel filler lid status switch LH harness connector and ground.

Monitor item

Condition

Status

F LID SW

Fuel filler lid status switch

ON

ON

OFF

OFF

(+)

(–)

Voltage

Fuel filler lid status switch

Connector

Terminal

B24

2

Ground

8 – 16 V

Sliding door control unit LH

Fuel filler lid status switch

Continuity 

Connector

Terminal

Connector

Terminal

B45

17

B24

2

Existed

Sliding door control unit LH

Ground

Continuity 

Connector

Terminal

B45

17

Not existed

FUEL LID STATUS SWITCH

DLK-339

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK FUEL FILLER LID STATUS SWITCH

Refer to 

DLK-339, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace fuel filler interlock assembly.

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000009649282

1.

CHECK FUEL FILLER LID STATUS SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect fuel filler lid status switch connector.

3.

Check continuity between fuel filler lid status switch terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace fuel filler lid interlock assembly.

Fuel filler lid status switch

Ground

Continuity 

Connector

Terminal

B24

1

Existed

Fuel filler lid status switch

Condition

Continuity

Terminal

2

1

Fuel filler lid status switch

ON

Existed

OFF

Not existed

DLK-340

< DTC/CIRCUIT DIAGNOSIS >

SLIDING DOOR OPEN/CLOSE SWITCH

SLIDING DOOR OPEN/CLOSE SWITCH

FRONT LH

FRONT LH : Component Function Check

INFOID:0000000009649283

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR” using CONSULT.

2.

Select “DRIVER SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Sliding door open/close switch (front LH) is OK.

NO

>> Refer to 

DLK-340, "FRONT LH : Diagnosis Procedure"

.

FRONT LH : Diagnosis Procedure

INFOID:0000000009649284

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (front side) connector.

3.

Check voltage between sliding door open/close switch (front side) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH CIRCUIT

1.

Disconnect sliding door control unit LH connector.

2.

Check continuity between sliding door control unit LH harness connector and sliding door open/close
switch (front side) harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door control unit LH. Refer to 

DLK-500, "LH : Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH GROUND CIRCUIT

Check continuity between sliding door open/close switch (front side) harness connector and ground.

Monitor item

Condition

Status

DRIVER SW

Sliding door open/close switch 
(front LH)

Pressed

ON

Released

OFF

(+)

(–)

Voltage

Sliding door open/close switch (front side)

Connector

Terminal

M90

2

Ground

8 – 16 V

Sliding door control unit LH

Sliding door open/close switch (front side)

Continuity 

Connector

Terminal

Connector

Terminal

B45

19

M90

2

Existed

Sliding door control unit LH

Ground

Continuity 

Connector

Terminal

B45

19

Not existed

SLIDING DOOR OPEN/CLOSE SWITCH

DLK-341

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

Refer to 

DLK-341, "FRONT LH : Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace sliding door open/close switch (front side).

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-42, "Intermittent Incident"

.

>> INSPECTION END

FRONT LH : Component Inspection

INFOID:0000000009649285

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (front side) connector.

3.

Check continuity between sliding door open/close switch (front side) terminals.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace sliding door open/close switch (front side).

FRONT RH

FRONT RH : Component Function Check

INFOID:0000000009649286

1.

CHECK FUNCTION

1.

Select “AUTO SLDE DOOR RIGHT” using CONSULT.

2.

Select “DRIVER SW” in “DATA MONITOR” mode.

3.

Check that the function operates normally according to the following conditions.

Is the inspection result normal?

YES

>> Sliding door open/close switch (front RH) is OK.

NO

>> Refer to 

DLK-341, "FRONT RH : Diagnosis Procedure"

.

FRONT RH : Diagnosis Procedure

INFOID:0000000009649287

1.

CHECK SLIDING DOOR OPEN/CLOSE SWITCH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect sliding door open/close switch (front side) connector.

Sliding door open/close switch (front side)

Ground

Continuity 

Connector

Terminal

M90

3

Existed

Sliding door open/close switch (front side)

Condition

Continuity

Terminal

2

3

Sliding door open/close switch 
(front LH)

Pressed

Existed

Released

Not existed

Monitor item

Condition

Status

DRIVER SW

Sliding door open/close switch 
(front RH)

Pressed

ON

Released

OFF

 

 

 

 

 

 

 

Content   ..  404  405  406  407   ..