Nissan Quest E52. Manual - part 365

 

  Index      Nissan     Nissan Quest E52 (2011-2014 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  363  364  365  366   ..

 

 

Nissan Quest E52. Manual - part 365

 

 

DLK-174

< DTC/CIRCUIT DIAGNOSIS >

B2401 IGNITION POWER SUPPLY CIRCUIT

B2401 IGNITION POWER SUPPLY CIRCUIT

AUTOMATIC BACK DOOR CONTROL MODULE

AUTOMATIC BACK DOOR CONTROL MODULE : DTC Logic

INFOID:0000000009649060

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Turn ignition switch ON and wait for at least 1 second.

2.

Check “Self Diagnostic Result” mode of “AUTO BACK DOOR” using CONSULT.

Is DTC detected?

YES

>> Refer to 

DLK-174, "AUTOMATIC BACK DOOR CONTROL MODULE : Diagnosis Procedure"

.

NO

>> INSPECTION END

AUTOMATIC BACK DOOR CONTROL MODULE : Diagnosis Procedure

INFOID:0000000009649061

1.

CHECK FUSE

1.

Turn ignition switch OFF.

2.

Check 10 A fuse, [No. 3, located in fuse block (J/B)].

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.

2.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect automatic back door control module connector.

3.

Check voltage between automatic back door control module harness connector and ground.

Is the measurement value normal?

YES

>> Check intermittent incident. Refer to 

GI-42, "Intermittent Incident"

.

NO

>> Repair or replace harness.

SLIDING DOOR LH

SLIDING DOOR LH : DTC Logic

INFOID:0000000009649062

DTC DETECTION LOGIC

DTC

CONSULT display 

description

DTC detecting condition

Possible cause

B2401

IGN OPEN

When the automatic back door control unit detects 
the following condition for 0.3 second or more
• Power supply condition (OFF) of automatic back 

door control unit and Ignition position signal (ON) 
from BCM via CAN

• Fuse
• Harness or connectors

(Ignition power supply condition 
circuit is open or shorted)

(+)

(

)

Condition

Voltage

Automatic back door control module

Connector

Terminal

B8

7

Ground

Ignition switch

ON

9 - 16 V

B2401 IGNITION POWER SUPPLY CIRCUIT

DLK-175

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

DTC CONFIRMATION PROCEDURE

1.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Turn ignition switch ON.

2.

Check “Self Diagnostic Result” mode of “AUTO SLIDE DOOR” using CONSULT.

Is DTC detected?

YES

>> Refer to 

DLK-175, "SLIDING DOOR LH : Diagnosis Procedure"

.

NO

>> INSPECTION END

SLIDING DOOR LH : Diagnosis Procedure

INFOID:0000000009649063

1.

CHECK FUSE

1.

Turn ignition switch OFF.

2.

Check 10A fuse, [No. 3, located in fuse block (J/B)].

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.

2.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect sliding door control unit LH connector.

3.

Check voltage between sliding door control unit LH harness connector and ground.

Is the measurement value normal?

YES

>> Check intermittent incident. Refer to 

GI-42, "Intermittent Incident"

.

NO

>> Repair or replace harness.

SLIDING DOOR RH

SLIDING DOOR RH : DTC Logic

INFOID:0000000009649064

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Turn ignition switch ON.

2.

Check “Self Diagnostic Result” mode of “AUTO SLIDE DOOR RIGHT” using CONSULT.

DTC

CONSULT display 

description

DTC detecting condition

Possible cause

B2401

IGN OPEN

When the sliding door control unit detects the fol-
lowing condition for 0.3 second or more
• Power supply condition (OFF) of sliding door 

control unit and ignition position signal (ON) from 
BCM via CAN

• Fuse
• Harness or connectors

(Ignition power supply condition 
circuit is open or shorted)

(+)

(

)

Condition

Voltage

Sliding door control unit LH

Connector

Terminal

B45

6

Ground

Ignition switch

ON

9 – 16 V

DTC

CONSULT display 

description

DTC detecting condition

Possible cause

B2401

IGN OPEN

When the sliding door control unit detects the fol-
lowing condition for 0.3 second or more
• Power supply condition (OFF) of sliding door 

control unit and ignition position signal (ON) from 
BCM via CAN

• Fuse
• Harness or connectors

(Ignition power supply condition 
circuit is open or shorted)

DLK-176

< DTC/CIRCUIT DIAGNOSIS >

B2401 IGNITION POWER SUPPLY CIRCUIT

Is DTC detected?

YES

>> Refer to 

DLK-176, "SLIDING DOOR RH : Diagnosis Procedure"

.

NO

>> INSPECTION END

SLIDING DOOR RH : Diagnosis Procedure

INFOID:0000000009649065

1.

CHECK FUSE

1.

Turn ignition switch OFF.

2.

Check 10A fuse, [No. 3, located in fuse block (J/B)].

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Replace the blown fuse after repairing the affected circuit if a fuse is blown.

2.

CHECK POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect sliding door control unit RH connector.

3.

Check voltage between sliding door control unit RH harness connector and ground.

Is the measurement value normal?

YES

>> Check intermittent incident. Refer to 

GI-42, "Intermittent Incident"

.

NO

>> Repair or replace harness.

(+)

(

)

Condition

Voltage

Sliding door control unit RH

Connector

Terminal

B247

6

Ground

Ignition switch

ON

9 – 16 V

B2402 TOUCH SENSOR

DLK-177

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

B2402 TOUCH SENSOR

SLIDING DOOR LH

SLIDING DOOR LH : DTC Logic

INFOID:0000000009649066

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Turn ignition switch ON.

2.

Check “Self Diagnostic Result” mode of “AUTO SLIDE DOOR” using CONSULT.

Is DTC detected?

YES

>> Refer to 

DLK-177, "SLIDING DOOR LH : Diagnosis Procedure"

.

NO

>> INSPECTION END

SLIDING DOOR LH : Diagnosis Procedure

INFOID:0000000009649067

1.

CHECK SLIDING DOOR TOUCH SENSOR INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Check voltage between sliding door touch sensor LH harness connector and sliding door control unit LH
harness connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR TOUCH SENSOR CIRCUIT

1.

Disconnect sliding door control unit LH connector and sliding door touch sensor LH connector.

2.

Check continuity between sliding door control unit LH harness connector and sliding door touch sensor
LH harness connector.

3.

Check continuity between sliding door control unit LH harness connector and ground.

Is the inspection result normal?

DTC

CONSULT display 

description

DTC detecting condition

Possible cause

B2402

TOUCH SENSOR 
OPEN

When the sliding door control unit detects the open 
circuit of the sliding door touch sensor

• Sliding door touch sensor
• Harness or connector

(Sliding door touch sensor circuit is 
open)

• Sliding door control unit

(+)

(–)

Condition

Voltage

Sliding door touch sensor 

LH

Sliding door control unit 

LH

 Connector

Terminal

 Connector

Terminal

D172

1

B45

23

Sliding door touch 
sensor LH

Pinching detection

0 – 1.5 V

Other than above

4 – 8 V

Sliding door control unit LH

Sliding door touch sensor LH

Continuity 

 Connector

Terminal

Connector

Terminal

B45

24

D172

1

Existed

Sliding door control unit LH

Ground

Continuity 

 Connector

Terminal

B45

24

Not existed

 

 

 

 

 

 

 

Content   ..  363  364  365  366   ..