EC-464 < DTC/CIRCUIT DIAGNOSIS > [MRA8DE] COOLING FAN 4. CHECK INTERMITTENT INCIDENT Check intermittent incident. Refer to GI-39, "Intermittent Incident" . Is the inspection result normal? YES >> Check IPDM E/R. Refer to PCS-10, "CONSULT Function (IPDM E/R)" (With intelligent key sys- PCS-38, "CONSULT Function (IPDM E/R)" (Without intelligent key system). NO >> Repair or replace error-detected parts. Component Inspection (Cooling Fan Motor) INFOID:0000000009758723 1. CHECK COOLING FAN MOTOR Supply cooling fan motor terminals with battery voltage and check operation. Is the inspection result normal? YES >> INSPECTION END NO >> Replace cooling fan motor. Refer to CO-17, "Removal and Installation" Cooling fan motor Condition Operation Terminal + − 1 4 12 V direct current supply Cooling fan operates. No supply Cooling fan not operates. 2 3 12 V direct current supply Cooling fan operates. No supply Cooling fan not operates. |