C1A6D BRAKE POWER SUPPLY BACKUP UNIT BR-149 < DTC/CIRCUIT DIAGNOSIS > C D E G H I J K L M A B BR N O P Be sure to wait for 5 seconds or more after turning the power switch OFF. 3. Turn the power switch OFF to exit CONSULT, and disconnect CONSULT from data link connector. 4. Close all doors (including back door), check that the room lamp is OFF, get out of the vehicle, and wait for 3 minutes or more with all doors closed. CAUTION: Never operate the vehicle while waiting. 5. Turn the power switch ON without depressing the brake pedal. CAUTION: Never set the vehicle to READY. 6. Start CONSULT and erase self-diagnosis result of “BRAKE”. 7. Turn the power switch OFF to exit CONSULT, and disconnect CONSULT from data link connector. 8. Close all doors (including back door), check that the room lamp is OFF, get out of the vehicle, and wait for 3 minutes or more with all doors closed. CAUTION: Never operate the vehicle while waiting. 9. Turn the power switch ON without depressing the brake pedal. CAUTION: Never set the vehicle to READY. 10. Depress brake pedal by 100 mm (3.94 in) or more, and hold the position for 5 seconds or more. 11. Release brake pedal. 12. Start CONSULT and perform “BRAKE” self-diagnosis. YES >> GO TO 15. NO >> INSPECTION END 15. CHECK BRAKE POWER SUPPLY BACKUP UNIT CIRCUIT 1. Turn the power switch OFF to exit CONSULT, and disconnect CONSULT from data link connector. 2. Close all doors (including back door), check that the room lamp is OFF, get out of the vehicle, and wait for 3 minutes or more with all doors closed. CAUTION: Never operate the vehicle while waiting. 3. Disconnect 12V battery cable from negative terminal. Refer to BR-6, "Precaution for Removing 12V Bat- 4. Disconnect the electrically-driven intelligent brake unit harness connector. 5. Disconnect the brake power supply backup unit harness connector. 6. Check the continuity between electrically-driven intelligent brake unit and brake power supply backup unit. 7. Check the continuity between brake power supply backup unit and ground. Is the inspection result normal? YES >> Replace the brake power supply backup unit. Refer to BR-513, "Removal and Installation" NO >> Repair or replace error-detected parts. Electrically-driven intelligent brake unit Brake power supply backup unit Continuity Connector Terminal Connector Terminal E34 31 B15 1 Existed 31 4 Not existed 31 5 Not existed 31 6 Not existed Brake power supply backup unit — Continuity Connector Terminal B15 1 Ground Not existed |