DTC P0132, P0152 HO2S1 EC-771 [VG33E] C D E F G H I J K L M A EC Specification data are reference values and are measured between each terminal and ground. CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam- : Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope. TER- MINAL NO. WIRE COLOR ITEM CONDITION DATA (DC Voltage) 50 B Heated oxygen sensor [Engine is running] ● Warm-up condition ● Engine speed is 2,000 rpm 0 - Approximately 1.0V SEF002V |