DLK-246 < SYMPTOM DIAGNOSIS > HAZARD AND HORN REMINDER DOES NOT OPERATE HAZARD AND HORN REMINDER DOES NOT OPERATE Diagnosis Procedure INFOID:0000000009175821 1. CHECK “HAZARD ANSWER BACK” SETTING IN “WORK SUPPORT” 1. Select “INTELLIGENT KEY” of “BCM” using CONSULT. 2. Select “HAZARD ANSWER BACK” in “WORK SUPPORT” mode. 3. Check the “HAZARD ANSWER BACK” setting in “WORK SUPPORT”. BCS-21, "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIGENT KEY)" . Is the inspection result normal? YES >> GO TO 2. NO >> Set the “Lock Only”, “Unlock Only” or “Lock/Unlock” in “HAZARD ANSWER BACK”. 2. CHECK “HORN WITH KEYLESS LOCK” SETTING IN “WORK SUPPORT” 1. Select “INTELLIGENT KEY” of “BCM” using CONSULT. 2. Select “HORN WITH KEYLESS LOCK” in “WORK SUPPORT” mode. 3. Check the “HORN WITH KEYLESS LOCK” in “WORK SUPPORT”. BCS-21, "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIGENT KEY)" . Is the inspection result normal? YES >> GO TO 3. NO >> Set the “On” in “HORN WITH KEYLESS LOCK”. 3. CHECK HAZARD FUNCTION Check hazard function. DLK-206, "Component Function Check" Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace the malfunctioning parts. 4. CHECK HORN FUNCTION Check horn function. SEC-135, "Component Function Check" Is the inspection result normal? YES >> GO TO 5. NO >> Repair or replace the malfunctioning parts. 5. REPLACE BCM • Replace BCM. Refer to BCS-80, "Removal and Installation" . • Confirm the operation after replacement. YES >> Inspection End. NO >> Check intermittent incident. Refer to GI-49, "Intermittent Incident" . |