DLK-234 < SYMPTOM DIAGNOSIS > DOOR DOES NOT LOCK/UNLOCK WITH DOOR KEY CYLINDER OPERATION DOOR DOES NOT LOCK/UNLOCK WITH DOOR KEY CYLINDER OPERA- Diagnosis Procedure INFOID:0000000009175804 1. CHECK POWER DOOR LOCK OPERATION Check power door lock operation. YES >> GO TO 2. NO >> Refer to DLK-231, "ALL DOOR : Diagnosis Procedure" 2. CHECK DOOR KEY CYLINDER SWITCH Check door key cylinder switch. DLK-191, "Component Function Check" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. REPLACE BCM • Replace BCM. Refer to BCS-80, "Removal and Installation" . • Confirm the operation after replacement. YES >> Inspection End. NO >> Check intermittent incident. Refer to GI-49, "Intermittent Incident" . |