DLK-206 < DTC/CIRCUIT DIAGNOSIS > HAZARD FUNCTION HAZARD FUNCTION Component Function Check INFOID:0000000009175762 1. CHECK FUNCTION 1. Select “INTELLIGENT KEY” of “BCM” using CONSULT. 2. Select “FLASHER” in “ACTIVE TEST” mode. 3. Touch “LH” or “RH” to check that it works normally. YES >> Hazard warning lamp circuit is OK. NO >> Refer to DLK-206, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000009175763 1. CHECK HAZARD SWITCH CIRCUIT EXL-127, "Component Function Check" . Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace the malfunctioning parts. 2. CHECK INTERMITTENT INCIDENT GI-49, "Intermittent Incident" >> Inspection End. |