Content .. 1063 1064 1065 1066 ..
B2608 STARTER RELAY SEC-123 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P 3. CHECK STARTER RELAY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect IPDM E/R connector. 3. Disconnect BCM connector. 4. Check continuity between IPDM E/R harness connector and BCM harness connector. 5. Check continuity between IPDM E/R harness connector and ground. Is the inspection result normal? YES >> Replace IPDM E/R. Refer to PCS-32, "Removal and Installation" . NO >> Repair or replace harness. 4. CHECK INTERMITTENT INCIDENT GI-49, "Intermittent Incident" . >> Inspection End. IPDM E/R BCM Continuity Connector Terminal Connector Terminal E119 33 M19 62 Yes IPDM E/R Ground Continuity Connector Terminal E119 33 No |