EC-296

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0448 EVAP CANISTER VENT CONTROL VALVE

P0448 EVAP CANISTER VENT CONTROL VALVE

Description

INFOID:0000000003591645

The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows “EVAP
Control System” diagnosis.

DTC Logic

INFOID:0000000003388068

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Turn ignition switch ON.

3.

Turn ignition switch OFF and wait at least 10 seconds.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

With CONSULT-III

1.

Turn ignition switch ON and wait at least 5 seconds.

2.

Turn ignition switch OFF and wait at least 10 seconds.

3.

Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.

4.

Start engine and let it idle for at least 1 minute. 

5.

Repeat next procedures 3 times.

-

Increase the engine speed up to 3,000 to 3,500 rpm and keep it for 2 minutes and 50 seconds to 3 min-
utes.

Never exceed 3 minutes.

-

Fully released accelerator pedal and keep engine idle for about 5 seconds.

6.

Repeat next procedure 20 times.

-

Quickly increase the engine speed up to 4,000 to 4,500 rpm or more and keep it for 25 to 30 seconds.

PBIB1263E

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0448

EVAP canister vent con-
trol valve close

EVAP canister vent control valve remains 
closed under specified driving conditions.

• EVAP canister vent control valve
• EVAP control system pressure sensor 

and the circuit

• Blocked rubber tube to EVAP canister 

vent control valve

• EVAP canister is saturated with water

Revision: 2008 October

2009 Murano

P0448 EVAP CANISTER VENT CONTROL VALVE

EC-297

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

-

Fully released accelerator pedal and keep engine idle for at least 35 seconds.

7.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-297, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000003388069

1.

CHECK RUBBER TUBE

1.

Turn ignition switch OFF.

2.

Disconnect rubber tube connected to EVAP canister vent control valve.

3.

Check the rubber tube for clogging.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Clean rubber tube using an air blower.

2.

CHECK EVAP CANISTER VENT CONTROL VALVE

Refer to 

EC-298, "Component Inspection"

.

Is he inspection result normal?

YES

>> GO TO 3.

NO

>> Replace EVAP canister vent control valve.

3.

CHECK IF EVAP CANISTER SATURATED WITH WATER

1.

Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.

2.

Check if water will drain from the EVAP canister.

Does water drain from the EVAP canister?

YES

>> GO TO 4.

NO

>> GO TO 6.

4.

CHECK EVAP CANISTER

Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be less than 2.1 kg (4.6 lb).

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> GO TO 5.

5.

DETECT MALFUNCTIONING PART

Check the following.
• EVAP canister for damage

PBIB0972E

JMBIA1134GB

Revision: 2008 October

2009 Murano

EC-298

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0448 EVAP CANISTER VENT CONTROL VALVE

• EVAP hose between EVAP canister and vehicle frame for clogging or poor connection

>> Repair hose or replace EVAP canister.

6.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check that water is not inside connectors.

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> Replace EVAP control system pressure sensor.

7.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-302, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Replace EVAP control system pressure sensor.

8.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-40, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000003733511

1.

CHECK EVAP CANISTER VENT CONTROL VALVE-I

1.

Remove EVAP canister vent control valve from EVAP canister.

2.

Check portion (A) of EVAP canister vent control valve for rust.

Is it rusted?

YES

>> Replace EVAP canister vent control valve.

NO

>> GO TO 2.

2.

CHECK EVAP CANISTER VENT CONTROL VALVE-II

With CONSULT-III

1.

Reconnect harness connectors disconnected.

2.

Turn ignition switch ON.

3.

Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.

4.

Check air passage continuity and operation delay time.
Check that new O-ring is installed properly.

Operation takes less than 1 second.

Without CONSULT-III

1.

Disconnect EVAP canister vent control valve harness connector.

2.

Check air passage continuity and operation delay time under the
following conditions.

Check that new O-ring is installed properly.

JMBIA0168ZZ

Condition VENT CONTROL/V

Air passage continuity between (A) and (B)

ON

Not existed

OFF

Existed

JMBIA0169ZZ

Revision: 2008 October

2009 Murano

P0448 EVAP CANISTER VENT CONTROL VALVE

EC-299

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

Operation takes less than 1 second.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> GO TO 3.

3.

CHECK EVAP CANISTER VENT CONTROL VALVE-III

With CONSULT-III

1.

Clean the air passage [portion (A) to (B)] of EVAP canister vent control valve using an air blower.

2.

Perform “VENT CONTROL/V” in “ACTIVE TEST” mode.

3.

Check air passage continuity and operation delay time.
Check that new O-ring is installed properly.

Operation takes less than 1 second.

Without CONSULT-III

1.

Clean the air passage [portion (A) to (B)] of EVAP canister vent
control valve using an air blower.

2.

Check air passage continuity and operation delay time under the
following conditions.
Check that new O-ring is installed properly.

Operation takes less than 1 second.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace EVAP canister vent control valve

Condition

Air passage continuity between (A) and (B)

12 V direct current supply between
 terminals 1 and 2

Not existed

OFF

Existed

Condition VENT CONTROL/V

Air passage continuity between (A) and (B)

ON

No

OFF

Yes

Condition

Air passage continuity between (A) and (B)

12 V direct current supply between
 terminals (1) and (2)

No

OFF

Yes

JMBIA0169ZZ

Revision: 2008 October

2009 Murano

EC-300

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR

P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR

Description

INFOID:0000000003388071

The EVAP control system pressure sensor detects pressure in the
purge line. The sensor output voltage to the ECM increases as pres-
sure increases.

DTC Logic

INFOID:0000000003388072

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Turn ignition switch ON.

3.

Turn ignition switch OFF and wait at least 10 seconds.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1.

Start engine and wait at least 40 seconds.
NOTE:
Do not depress accelerator pedal even slightly.

2.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-300, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000003388073

1.

CHECK GROUND CONNECTION

1.

Turn ignition switch OFF.

2.

Check ground connection E38. Refer to Ground Inspection in 

GI-43, "Circuit Inspection"

.

Is the inspection result normal?

PBIB3370E

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0451

EVAP control system 
pressure sensor perfor-
mance

ECM detects a sloshing signal from the EVAP 
control system pressure sensor

• Harness or connectors

(EVAP control system pressure sensor 
circuit is shorted.)
[CKP sensor (POS) circuit is shorted.]
(APP sensor 2 circuit is shorted.)
(Refrigerant pressure sensor circuit is 
shorted.)

• EVAP control system pressure sensor
• Crankshaft position sensor (POS)
• Accelerator pedal position sensor
• Refrigerant pressure sensor

Revision: 2008 October

2009 Murano

P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-301

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

YES

>> GO TO 2.

NO

>> Repair or replace ground connection.

2.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check that water is not inside connectors.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness connector.

3.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT

1.

Turn ignition switch ON.

2.

Check the voltage between EVAP control system pressure sensor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> GO TO 4.

4.

CHECK SENSOR POWER SUPPLY CIRCUIT

Check harness for short to power and short to ground, between the following terminals.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair short to ground or short to power in harness or connectors.

5.

CHECK COMPONENTS

Check the following.
• Crankshaft position sensor (POS) (Refer to 

EC-263, "Component Inspection"

.)

• Refrigerant pressure sensor (Refer to 

EC-463, "Diagnosis Procedure"

.)

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Replace malfunctioning components.

6.

CHECK APP SENSOR

Refer to 

EC-415, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 9.

NO

>> GO TO 7.

7.

REPLACE ACCELERATOR PEDAL ASSEMBLY

1.

Replace accelerator pedal assembly.

2.

Go to 

EC-415, "Special Repair Requirement"

.

>> INSPECTION END

8.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

EVAP control system pressure sensor

Ground

Voltage (V)

Connector

Terminal

B17

3

Ground

Approx. 5

ECM

Sensor

Connector

Terminal

Name

Connector

Terminal

F8

72

Refrigerant pressure sensor

E300

1

76

CKP sensor (POS)

F20

1

E16

87

APP sensor

E110

5

91

EVAP control system pressure sensor

B17

3

Revision: 2008 October

2009 Murano

EC-302

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-302, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 9.

NO

>> Replace EVAP control system pressure sensor.

9.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-40, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000003388078

1.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

1.

Turn ignition switch OFF.

2.

Remove EVAP control system pressure sensor with its harness connector.
Always replace O-ring with a new one.

3.

Install a vacuum pump to EVAP control system pressure sensor.

4.

Turn ignition switch ON and check output voltage between ECM terminals under the following conditions.

CAUTION:

• Always calibrate the vacuum pump gauge when using it.
• Never apply below -93.3 kPa (-0.952 kg/cm

2

, -13.53 psi) or pressure over 101.3 kPa (1.033 kg/cm

2

,

14.69 psi).

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace EVAP control system pressure sensor

ECM

Applied vacuum kPa

(kg/cm

2

, psi)

Voltage

Connector

+

Terminal

Terminal

E16

86

(EVAP control system 

pressure sensor signal)

96

(Sensor ground)

Not applied

1.8 - 4.8 V

-26.7 (-0.272, -3.87)

2.1 to 2.5 V lower than 

above value

Revision: 2008 October

2009 Murano

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-303

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

Description

INFOID:0000000003591654

The EVAP control system pressure sensor detects pressure in the
purge line. The sensor output voltage to the ECM increases as pres-
sure increases.

DTC Logic

INFOID:0000000003388076

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Turn ignition switch ON.

3.

Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION:
Always perform test at a temperature of 5

°

C (41

°

F) or more.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

With CONSULT-III

1.

Start engine and warm it up to normal operating temperature.

2.

Turn ignition switch OFF and wait at least 10 seconds.

3.

Turn ignition switch ON.

4.

Turn ignition switch OFF and wait at least 10 seconds.

5.

Turn ignition switch ON.

6.

Select “DATA MONITOR” mode with CONSULT-III.

7.

Check that “FUEL T/TMP SE” is more than 0

°

C (32

°

F).

8.

Start engine and wait at least 20 seconds.

9.

Check 1st trip DTC.

With GST

1.

Start engine and warm it up to normal operating temperature.

2.

Set voltmeter probes to ECM harness connector terminals under the following conditions.

PBIB3370E

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0452

EVAP control system 
pressure sensor low in-
put

An excessively low voltage from the sensor is 
sent to ECM.

• Harness or connectors

(The sensor circuit is open or shorted.)
[CKP sensor (POS) circuit is shorted.]
(APP sensor 2 circuit is shorted.)
(Refrigerant pressure sensor circuit is 
shorted.)

• EVAP control system pressure sensor
• Crankshaft position sensor (POS)
• Accelerator pedal position sensor
• Refrigerant pressure sensor

Revision: 2008 October

2009 Murano

EC-304

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

3.

Check that the voltage is less than 4.2 V.

4.

Turn ignition switch OFF and wait at least 10 seconds.

5.

Turn ignition switch ON.

6.

Turn ignition switch OFF and wait at least 10 seconds.

7.

Start engine and wait at least 20 seconds.

8.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-304, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000003388077

1.

CHECK GROUND CONNECTION

1.

Turn ignition switch OFF.

2.

Check ground connection E38. Refer to Ground Inspection in 

GI-43, "Circuit Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace ground connection.

2.

CHECK CONNECTOR

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check that water is not inside connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness connector.

3.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-I

1.

Turn ignition switch ON.

2.

Check the voltage between EVAP control system pressure sensor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 10.

NO

>> GO TO 4.

4.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

Is the inspection result normal?

YES

>> GO TO 6.

ECM

Connector

+

Terminal

Terminal

E16

95

(Fuel tank temperature sensor signal)

104

(Sensor ground)

EVAP control system pressure sensor

Ground

Voltage (V)

Connector

Terminal

B17

3

Ground

Approx. 5

EVAP control system pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B17

3

E16

91

Existed

Revision: 2008 October

2009 Murano

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-305

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

NO

>> GO TO 5.

5.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit.

6.

CHECK SENSOR POWER SUPPLY CIRCUIT

Check harness for short to power and short to ground, between the following terminals.

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> Repair short to ground or short to power in harness or connectors.

7.

CHECK COMPONENTS

Check the following.
• Crankshaft position sensor (POS) (Refer to 

EC-263, "Component Inspection"

.)

• Refrigerant pressure sensor (Refer to 

EC-463, "Diagnosis Procedure"

.)

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Replace malfunctioning components.

8.

CHECK APP SENSOR

Refer to 

EC-415, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 15.

NO

>> GO TO 9.

9.

REPLACE ACCELERATOR PEDAL ASSEMBLY

1.

Replace accelerator pedal assembly.

2.

Refer to 

EC-415, "Special Repair Requirement"

.

>> INSPECTION END

10.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND

SHORT

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

4.

Also check harness for short to ground and short to power.

Is the inspection result normal?

ECM

Sensor

Connector

Terminal

Name

Connector

Terminal

F8

72

Refrigerant pressure sensor

E300

1

76

CKP sensor (POS)

F20

1

E16

87

APP sensor

E110

5

91

EVAP control system pressure sensor

B17

3

EVAP control system pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B17

1

E16

96

Existed

Revision: 2008 October

2009 Murano

EC-306

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

YES

>> GO TO 12.

NO

>> GO TO 11.

11.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit, short to ground or short to power in harness or connectors.

12.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND

SHORT

1.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

2.

Also check harness for short to ground and short to power.

Is the inspection result normal?

YES

>> GO TO 14.

NO

>> GO TO 13.

13.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit, short to ground or short to power in harness or connectors.

14.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-306, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 15.

NO

>> Replace EVAP control system pressure sensor.

15.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-40, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000003625710

1.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

1.

Turn ignition switch OFF.

2.

Remove EVAP control system pressure sensor with its harness connector.
Always replace O-ring with a new one.

3.

Install a vacuum pump to EVAP control system pressure sensor.

4.

Turn ignition switch ON and check output voltage between ECM terminals under the following conditions.

EVAP control system pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B17

2

E16

86

Existed

Revision: 2008 October

2009 Murano

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-307

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

CAUTION:

• Always calibrate the vacuum pump gauge when using it.
• Never apply below -93.3 kPa (-0.952 kg/cm

2

, -13.53 psi) or pressure over 101.3 kPa (1.033 kg/cm

2

,

14.69 psi).

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace EVAP control system pressure sensor

ECM

Applied vacuum kPa

(kg/cm

2

, psi)

Voltage

Connector

+

Terminal

Terminal

E16

86

(EVAP control system 

pressure sensor signal)

96

(Sensor ground)

Not applied

1.8 - 4.8 V

-26.7 (-0.272, -3.87)

2.1 to 2.5 V lower than 

above value

Revision: 2008 October

2009 Murano

EC-308

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

Description

INFOID:0000000003591658

The EVAP control system pressure sensor detects pressure in the
purge line. The sensor output voltage to the ECM increases as pres-
sure increases.

DTC Logic

INFOID:0000000003388080

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-
ing the next test.
1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Turn ignition switch ON.

3.

Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION:
Always perform test at a temperature of 5

°

C (41

°

F) or more.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

With CONSULT-III

1.

Start engine and warm it up to normal operating temperature.

2.

Turn ignition switch OFF and wait at least 10 seconds.

3.

Turn ignition switch ON.

4.

Turn ignition switch OFF and wait at least 10 seconds.

5.

Turn ignition switch ON.

6.

Select “DATA MONITOR” mode with CONSULT-III.

7.

Check that “FUEL T/TMP SE” is more than 0

°

C (32

°

F).

8.

Start engine and wait at least 20 seconds.

9.

Check 1st trip DTC.

PBIB3370E

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0453

EVAP control system 
pressure sensor high in-
put

An excessively high voltage from the sensor is 
sent to ECM.

• Harness or connectors

(The sensor circuit is open or shorted.)
[CKP sensor (POS) circuit is shorted.]
(APP sensor 2 circuit is shorted.)
(Refrigerant pressure sensor circuit is 
shorted.)

• EVAP control system pressure sensor
• Crankshaft position sensor (POS)
• Accelerator pedal position sensor
• Refrigerant pressure sensor
• EVAP canister vent control valve
• EVAP canister
• Rubber hose from EVAP canister vent 

control valve to vehicle frame

Revision: 2008 October

2009 Murano

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-309

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

With GST

1.

Start engine and warm it up to normal operating temperature.

2.

Set voltmeter probes to ECM harness connector terminals.

3.

Check that the voltage is less than 4.2 V.

4.

Turn ignition switch OFF and wait at least 10 seconds.

5.

Turn ignition switch ON.

6.

Turn ignition switch OFF and wait at least 10 seconds.

7.

Start engine and wait at least 20 seconds.

8.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-309, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000003388081

1.

CHECK GROUND CONNECTION

1.

Turn ignition switch OFF.

2.

Check ground connection E38. Refer to Ground Inspection in 

GI-43, "Circuit Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace ground connection.

2.

CHECK CONNECTOR

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check that water is not inside connectors.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness connector.

3.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT

1.

Turn ignition switch ON.

2.

Check the voltage between EVAP control system pressure sensor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 10.

NO

>> GO TO 4.

4.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

ECM

Connector

+

Terminal

Terminal

E16

95

(Fuel tank temperature sensor signal)

104

(Sensor ground)

EVAP control system pressure sensor

Ground

Voltage (V)

Connector

Terminal

B17

3

Ground

Approx. 5

Revision: 2008 October

2009 Murano

EC-310

< COMPONENT DIAGNOSIS >

[VQ35DE]

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> GO TO 5.

5.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit.

6.

CHECK SENSOR POWER SUPPLY CIRCUIT

Check harness for short to power and short to ground, between the following terminals.

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> Repair short to ground or short to power in harness or connectors.

7.

CHECK COMPONENTS

Check the following.
• Crankshaft position sensor (POS) (Refer to 

EC-263, "Component Inspection"

.)

• Refrigerant pressure sensor (Refer to 

EC-463, "Diagnosis Procedure"

.)

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Replace malfunctioning components.

8.

CHECK APP SENSOR

Refer to 

EC-415, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 15.

NO

>> GO TO 9.

9.

REPLACE ACCELERATOR PEDAL ASSEMBLY

1.

Replace accelerator pedal assembly.

2.

Refer to 

EC-415, "Special Repair Requirement"

.

>> INSPECTION END

10.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND

SHORT

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

EVAP control system pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B17

3

E16

91

Existed

ECM

Sensor

Connector

Terminal

Name

Connector

Terminal

F8

72

Refrigerant pressure sensor

E300

1

76

CKP sensor (POS)

F20

1

E16

87

APP sensor

E110

5

91

EVAP control system pressure sensor

B17

3

Revision: 2008 October

2009 Murano

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-311

< COMPONENT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

4.

Also check harness for short to ground and short to power.

Is the inspection result normal?

YES

>> GO TO 12.

NO

>> GO TO 11.

11.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit, short to ground or short to power in harness or connectors.

12.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND

SHORT

1.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

2.

Also check harness for short to ground and short to power.

Is the inspection result normal?

YES

>> GO TO 14.

NO

>> GO TO 13.

13.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B4, E104
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit, short to ground or short to power in harness or connectors.

14.

CHECK RUBBER TUBE

1.

Disconnect rubber tube connected to EVAP canister vent control valve.

2.

Check the rubber tube for clogging.

Is the inspection result normal?

YES

>> GO TO 15.

NO

>> Clean the rubber tube using an air blower, repair or replace rubber tube.

15.

CHECK EVAP CANISTER VENT CONTROL VALVE

Refer to 

EC-294, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 16.

NO

>> Replace EVAP canister vent control valve.

16.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-312, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 17.

NO

>> Replace EVAP control system pressure sensor.

EVAP control system pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B17

1

E16

96

Existed

EVAP control system pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B17

2

E16

86

Existed

Revision: 2008 October