Nissan X-Trail 32. Manual - part 58

 

  Главная      Nissan     Nissan X-Trail 32 - Service Manual

 

поиск по сайту            

 

 

 

 

 

 

 

 

 

содержание   ..  56  57  58  59   ..

 

 

Nissan X-Trail 32. Manual - part 58

 

 

AV-224

< DTC/CIRCUIT DIAGNOSIS >

[WITH NAVIGATION]

U1302 CAMERA POWER VOLT

With BSW

Without BSW

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Repair the harness or connectors.

6.

CHECK FRONT CAMERA POWER SUPPLY (1)

1.

Connect around view monitor control unit harness connector.

2.

Turn ignition switch ON.

3.

Check the voltage between around view monitor control unit terminals.

With BSW

Without BSW

Is the inspection result normal?

YES

>> GO TO 7.

NO

>> Replace around view monitor control unit. Refer to 

AV-268, "Removal and Installation"

.

7.

CHECK FRONT CAMERA POWER SUPPLY (2)

1.

Turn ignition switch OFF.

2.

Connect front camera harness connector.

3.

Turn ignition switch ON.

4.

Check the voltage between around view monitor control unit terminals.

With BSW

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M102

68

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M24

38

Not existed

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminal

(+)

(–)

Terminal

M102

68

70

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminal

(+)

(–)

Terminal

M24

38

37

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminal

(+)

(–)

Terminal

M102

68

70

6.0 V

AV

U1302 CAMERA POWER VOLT

AV-225

< DTC/CIRCUIT DIAGNOSIS >

[WITH NAVIGATION]

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

Without BSW

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Replace front camera. Refer to 

AV-269, "Removal and Installation"

.

8.

CHECK SIDE CAMERA RH POWER SUPPLY OUTPUT CIRCUIT (CHECK FOR SHORT CIRCUIT)

1.

Turn ignition switch OFF.

2.

Disconnect following harness connector .

-

Around view monitor control unit

-

Door mirror (passenger side) (LHD models)

-

Door mirror (driver side) (RHD models)

3.

Check the continuity between around view monitor control unit harness connector and ground.

LHD models with BSW

LHD models without BSW

RHD models with BSW

RHD models without BSW

Is the inspection result normal?

YES

>> GO TO 9.

NO

>> Repair the harness or connectors.

9.

CHECK SIDE CAMERA RH POWER SUPPLY (1)

1.

Connect around view monitor control unit harness connector.

2.

Turn ignition switch ON.

3.

Check the voltage between around view monitor control unit terminals.

LHD models with BSW

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminal

(+)

(–)

Terminal

M24

38

37

6.0 V

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M102

62

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M24

34

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M102

56

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M24

30

Not existed

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M102

62

64

6.0 V

AV-226

< DTC/CIRCUIT DIAGNOSIS >

[WITH NAVIGATION]

U1302 CAMERA POWER VOLT

LHD models without BSW

RHD models with BSW

RHD models without BSW

Is the inspection result normal?

YES

>> GO TO 10.

NO

>> Replace around view monitor control unit. Refer to 

AV-268, "Removal and Installation"

.

10.

CHECK SIDE CAMERA RH POWER SUPPLY (2)

1.

Turn ignition switch OFF.

2.

Connect following harness connector.

-

Door mirror (passenger side) (LHD models)

-

Door mirror (driver side) (RHD models)

3.

Turn ignition switch ON.

4.

Check the voltage between around view monitor control unit terminals.

LHD models with BSW

LHD models without BSW

RHD models with BSW

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M24

34

33

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M102

56

58

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M24

30

29

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M102

62

64

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M24

34

33

6.0 V

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M102

56

58

6.0 V

AV

U1302 CAMERA POWER VOLT

AV-227

< DTC/CIRCUIT DIAGNOSIS >

[WITH NAVIGATION]

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

RHD models without BSW

Is the inspection result normal?

YES

>> GO TO 11.

NO

>> Replace side camera RH. Refer to 

AV-271, "Removal and Installation"

.

11.

CHECK SIDE CAMERA LH POWER SUPPLY OUTPUT CIRCUIT (CHECK FOR SHORT CIRCUIT)

1.

Turn ignition switch OFF.

2.

Disconnect following harness connector .

-

Around view monitor control unit

-

Door mirror (driver side) (LHD models)

-

Door mirror (passenger side) (RHD models)

3.

Check the continuity between around view monitor control unit harness connector and ground.

LHD models with BSW

LHD models without BSW

RHD models with BSW

RHD models without BSW

Is the inspection result normal?

YES

>> GO TO 12.

NO

>> Repair the harness or connectors.

12.

CHECK SIDE CAMERA LH POWER SUPPLY (1)

1.

Connect around view monitor control unit harness connector.

2.

Turn ignition switch ON.

3.

Check the voltage between around view monitor control unit terminals.

LHD models with BSW

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M24

30

29

6.0 V

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M102

56

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M24

30

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M102

62

Not existed

Around view monitor control unit

Ground

Continuity

Connector

Terminal

M24

34

Not existed

Around view monitor control unit

Reference value

(Approx.)

Connector

Terminals

+

Terminal

M102

56

58

6.0 V

 

 

 

 

 

 

 

содержание   ..  56  57  58  59   ..