PCS-32 < ECU DIAGNOSIS INFORMATION > [IPDM E/R] IPDM E/R 90 (L) Ground Cooling fan relay-2 Output Cooling • Stop 9 – 16 V HI operation 0 – 1 V 94 (SB) Ground Battery current sensor Input Engine running ° C • Idling 3.3 V 95 (P) Ground A/C relay Output Engine A/C switch OFF 0 – 1 V A/C switch ON 9 – 16 V 96 (R) *2 (GR) *12 (L) *13 Ground ECM relay Output Ignition switch OFF 0 – 1 V • Ignition switch ON (For a few seconds after turning igni- 6 – 16 V 97 *8 (V) Ground Throttle control motor Output Ignition switch ON 0 – 1 V • When ignition switch is turned from OFF to ON • For a few seconds after turning igni- tion switch OFF 9 – 16 V 100 (BG) *14 (BR) *15 (GR) *16 Ground Ignition power supply Output Ignition switch OFF 0 – 1 V Ignition switch ON 6 – 16 V 101 Ground Ignition power supply Output Ignition switch OFF 0 – 1 V Ignition switch ON 6 – 16 V 102 *8 (GR) Ground Throttle control motor Output Ignition switch OFF 0 – 1 V • Ignition switch ON (For a few seconds after turning igni- 6 – 16 V 103 (R) *1 (Y) *11 (G) *19 Ground ECM relay Output Ignition switch OFF 0 – 1 V • Ignition switch ON (For a few seconds after turning igni- 6 – 16 V 105 (L) *1 (R) *17 (BR) *18 Ground ECM relay Output Ignition switch OFF 0 – 1 V • Ignition switch ON (For a few seconds after turning igni- 6 – 16 V 106 (GR) *1 (L) *2 Ground Fuel pump relay con- Output • Ignition switch OFF the ignition switch ON 0 – 1 V Approximately 1 second or more turning 6 – 16 V 108 (R) *1 (L) *2 Ground ECM relay Output Ignition switch OFF 0 – 1 V • Ignition switch ON (For a few seconds after turning igni- 6 – 16 V Terminal No. (Wire color) Description Condition Value Signal name Input/ Output + – |