Content .. 1524 1525 1526 1527 ..
ANTI-PINCH INSPECTION RF-15 < BASIC INSPECTION > C D E F G H I J L M A B RF N O P ANTI-PINCH INSPECTION Description INFOID:0000000010286634 Check anti-pinch function when the initialization of sunshade system is performed. Refer to Work Procedure INFOID:0000000010286635 1. CHECK ANTI-PINCH FUNCTION 1. Fully open the sunshade. 2. Place a piece of wood near fully closed position. 3. Close the sunshade completely with auto-slide close. 4. Check that sunshade opens fully and stops. CAUTION: • Perform initialization procedure setting when auto-slide operation or anti-pinch function does not operate normally. • Check that auto-slide operates before inspection when system initialization is performed. shade it may open. • Thermal cut out may occur if open/close operation is performed continuously. In this situation allow system to cool before re-use. Is the inspection result normal? YES >> INSPECTION END NO >> Perform initialization procedure. Refer to |