Content .. 1160 1161 1162 1163 ..
HAC-284 < DTC/CIRCUIT DIAGNOSIS > [MANUAL HEATER ] POWER SUPPLY AND GROUND CIRCUIT POWER SUPPLY AND GROUND CIRCUIT A/C AMP. A/C AMP. : Diagnosis Procedure INFOID:0000000010499420 1. CHECK FUSE 1. Turn ignition switch OFF. 2. Check 10 A fuse [No. 14 (without stop/start system), located in fuse block (J/B)], [No. 76 (with stop/start PG-104, "Fuse, Connector and Terminal Arrangement" Is the inspection result normal? YES >> GO TO 2. NO >> Replace the blown fuse after repairing the affected circuit if a fuse is blown. 2. CHECK A/C AMP. ACCESSORY POWER SUPPLY 1. Disconnect A/C amp. connector. 2. Turn ignition switch ON. 3. Check voltage between A/C amp. harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair harness or connector between A/C amp. and fuse. 3. CHECK A/C AMP. GROUND CIRCUIT FOR OPEN 1. Turn ignition switch OFF. 2. Check continuity between A/C amp. harness connector and ground. Is the inspection result normal? YES >> Replace A/C amp. Refer to HAC-295, "Removal and Installation" . NO >> Repair harness or connector. + − Voltage A/C amp. Connector Terminal M50 3 Ground 11 - 14 V A/C amp. — Continuity Connector Terminal M50 19 Ground Existed |