Content .. 1130 1131 1132 1133 ..
HAC-164 < SYSTEM DESCRIPTION > [MANUAL AIR CONDITIONING] DIAGNOSIS SYSTEM (A/C AMP.) DIAGNOSIS SYSTEM (A/C AMP.) Description INFOID:0000000010432512 Air conditioning system performs self-diagnosis, operation check, function diagnosis, and various settings CONSULT Function INFOID:0000000010432513 CONSULT performs the following functions via CAN communication with A/C amp. NOTE: ECU IDENTIFICATION Part number of A/C amp. can be checked. SELF-DIAGNOSIS RESULTS Diagnosis result that is judged by A/C amp. can be checked. Refer to . DATA MONITOR Input/output signal of A/C amp. can be checked. Display item list ECU Diagnostic item (CONSULT) A/C amp. HVAC Self Diagnostic Result Data Monitor Active Test Work support BCM BCM-AIR CONDITIONER Self Diagnostic Result Data Monitor ECM ENGINE Self Diagnostic Result Data Monitor IPDM E/R IPDM E/R Self Diagnostic Result Data Monitor Auto active test Diagnostic mode Description Ecu Identification Displays the part number of A/C amp. Self Diagnostic Result Displays the diagnosis results judged by A/C amp. Data Monitor Displays the input/output signal of A/C amp. Active Test The signals used to activate each device are forcibly supplied from A/C amp. Work support Changes the setting for each setting function and performs automatic adjustment of Monitor item [Unit] Description AMB TEMP SEN [ ° C ( ° F)] Ambient temperature value converted from ambient temperature signal received from INT TEMP SEN [ ° C ( ° F)] Evaporator fin temperature value converted from intake sensor signal received from in- AMB SEN CAL [ ° C ( ° F)] Ambient temperature value calculated by A/C amp. |