P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1005 < DTC/CIRCUIT DIAGNOSIS > [MR EXCEPT FOR NISMO RS MODELS] C D E F G H I J K L M A EC N P O P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR DTC Logic INFOID:0000000012198497 DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1. PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct- ing the next test. 1. Turn ignition switch OFF and wait at least 10 seconds. 2. Turn ignition switch ON. 3. Turn ignition switch OFF and wait at least 10 seconds. TESTING CONDITION: Always perform test at a temperature of 5 °C (41°F) or more. >> GO TO 2. 2. PERFORM DTC CONFIRMATION PROCEDURE With CONSULT 1. Start engine and warm it up to normal operating temperature. 2. Turn ignition switch OFF and wait at least 10 seconds. 3. Turn ignition switch ON. 4. Turn ignition switch OFF and wait at least 10 seconds. 5. Turn ignition switch ON. 6. Select “DATA MONITOR” mode with CONSULT. 7. Check that “FUEL T/TMP SE” is more than 0 °C (32°F). 8. Start engine and wait at least 20 seconds. 9. Check 1st trip DTC. With GST 1. Start engine and warm it up to normal operating temperature. 2. Set voltmeter probes to ECM harness connector terminals under the following conditions. 3. Check that the voltage is less than 4.2 V. 4. Turn ignition switch OFF and wait at least 10 seconds. 5. Turn ignition switch ON. 6. Turn ignition switch OFF and wait at least 10 seconds. 7. Start engine and wait at least 20 seconds. 8. Check 1st trip DTC. YES >> Proceed to EC-1006, "Diagnosis Procedure" . NO >> INSPECTION END DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition Possible cause P0452 EVAP SYS PRES SEN An excessively low voltage from the sensor • Harness or connectors (EVAP control system pressure sensor • EVAP control system pressure sensor ECM Connector + – Terminal E19 128 148 |