Mitsubishi Outlander (2013+). Manual - part 712

 

  Index      Mitsubishi     Mitsubishi Outlander - service repair manual 2013 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  710  711  712  713   ..

 

 

Mitsubishi Outlander (2013+). Manual - part 712

 

 

ETACS

CHASSIS ELECTRICAL

54A-333

CONNECTOR: C-421

ACB05926AB

Terminal 
No.

Terminal 
code

Check item

Check condition

Normal 
condition

1

2

W.HI

Windshield wiper (HI) output

When windshield wipers are 
operating at high speed

System 
voltage

3

TAR1

Position lamp (RH) output

With position lamp ON

System 
voltage

− 5

6

STP

Stop lamp switch power supply

Stop lamp switch: ON

System 
voltage

7

W.LO

Windshield wiper (LO) output

When windshield wipers are 
operating at low speed

System 
voltage

8

TAL1

Position lamp (LH) output

With position lamp ON

System 
voltage

9

BLP1

Inhibitor switch (R) input

Selector lever: R and ignition 
switch: ON

System 
voltage

10

DEFR

Defogger output

Defogger switch: ON

1 V or less

CONNECTOR: C-422

ACB05924AB

3

+BP

Power supply (fusible link No. 1)

Ignition switch: ON

System 
voltage

− 5

6

DEFO-1 

DEFO-2

Defogger output

Defogger switch: ON

1 V or less

7

8

HOSW

Horn switch input

Horn switch: ON

1 V or less

9

ST

Ignition switch (START) input

Ignition switch: START

System 
voltage

10 

− 11

12

+B, PWM Power supply (fusible link No. 20)

Ignition switch: ON

System 
voltage

13

ACC1

Power supply (fuse No. 22)

Ignition switch: ACC

System 
voltage

Terminal 
No.

Terminal 
code

Check item

Check condition

Normal 
condition

Terminal 
No.

Terminal 
code

Check item

Check condition

Normal 
condition

1

SLSO

Shift lock solenoid

When all the following conditions 
are met.

• Ignition switch: ON

• Brake pedal: depressed

System 
voltage

ETACS

CHASSIS ELECTRICAL

54A-334

ON-VEHICLE SERVICE

CUSTOMISATION FUNCTION

M1545002501550

By operating the M.U.T.-III ETACS system, the fol-
lowing functions can be customised. The pro-
grammed information is held even when the battery 
is disconnected.

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

Turn power 
source

Adjustment of 
turn-signal lamp 
operation condition

ACC or IG1

Operable with ACC or ON position

IG1

Operable with ON position (initial 
condition)

Comfort flasher

With/without 
comfort flasher 
function

Disable

No function

Enable

With function (initial condition)

Hazard answer 
back

Adjustment of the 
number of keyless 
hazard warning 
lamp answer back 
flashes

Lock:1, Unlock:2

LOCK: Flashes once, UNLOCK: Flashes 
twice (initial condition)

Lock:1, Unlock:0

LOCK: Flashes once, UNLOCK: No flash

Lock:0, Unlock:2

LOCK: No flash, UNLOCK: Flash twice

Lock:2, Unlock:1

LOCK: Flash twice, UNLOCK: Flash once

Lock:2, Unlock:0

LOCK: Flash twice, UNLOCK: No flash

Lock:0, Unlock:1

LOCK: No flash, UNLOCK: Flash once

Lock:0, Unlock:0

No function

ETACS

CHASSIS ELECTRICAL

54A-335

Front wiper 
operation

Adjustment of the 
intermittent 
windshield wiper 
operation <vehicles 
without lighting 
control sensor>

Normal INT

Intermittent wiper interval is fixed to 4 
seconds.

Variable INT

Intermittent wiper interval is calculated only 
by the wiper volume control.

Speed Sensitive

Intermittent wiper interval is calculated 
according to the intermittent wiper volume 
control and vehicle speed (initial 
condition).

Adjustment of the 
intermittent 
windshield wiper 
operation <vehicles 
with lighting control 
sensor>

Normal INT

Intermittent wiper interval is fixed to 4 
seconds.

Variable INT

Intermittent wiper interval is calculated only 
by the wiper volume control.

Speed Sensitive

Intermittent wiper interval is calculated 
according to the intermittent wiper volume 
control and vehicle speed.

Rain Sensitive

Intermittent wiper interval is calculated 
according to the intermittent wiper volume 
control and lighting control sensor (initial 
condition).

Front/rear wiper 
washer

Disabling or 
enabling 
washer-linked wiper 
function

Only Washer

No function

Washer & Wiper

With function: Without delayed finishing 
wipe function <Initial condition>

With after wipe

With function: With delayed finishing wipe 
function

Intermittent time 
of rear wiper

Adjustment of rear 
wiper interval

0 sec.

No wiper interval

4 sec.

4 seconds

8 sec.

8 seconds (initial condition)

16 sec.

16 seconds

Rear wiper Low 
speed mode

Disabling or 
enabling rear wiper 
continuous 
operation

Disable

No function

Enable

With function (initial condition)

Auto fold mirror

Electric folding door 
mirror automatic 
unfolding function 
<vehicles with 
electric retractable 
remote controlled 
door mirrors>

Not Auto

No synchronised operation

Open Vehicle SPD

Vehicle speed-dependent operation

Open/Close by IG

Ignition switch linked operation

OPN/CLS Keyless

Keyless entry linked operation (initial 
condition)

Sensitivity for 
auto lamp

Lighting control 
sensor sensitivity 
(illumination 
intensity) <vehicles 
with lighting control 
sensor>

Level 1 bright

High ambient brightness

Level 2 bright

Standard ambient brightness (initial 
condition)

Level 3

Low ambient brightness

Level 4 dark

Low-low ambient brightness

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

ETACS

CHASSIS ELECTRICAL

54A-336

Room lamp 
delay timer with 
door

Adjustment of 
interior lamp delay 
shutdown time

0 sec.

0 second (no delay shutdown time)

7.5 sec.

7.5 seconds

15 sec.

15 seconds (initial condition)

30 sec.

30 seconds

60 sec.

60 seconds

120 sec.

120 seconds

180 sec.

180 seconds

Head lamp auto 
cut customise

Adjustment of 
headlamp 
automatic shutdown 
function

Disable

No function

Enable (B-spec.)

With function (initial condition)

Interior lamp 
auto cut timer

Adjustment of 
interior lamp 
automatic shutdown 
function operation 
time

Disable

No function

3 min

3 minutes

30 min

30 minutes (initial condition)

60 min

60 minutes

Comfort flasher 
switch time

Switch operation 
time to activate the 
comfort flasher 
function

Normal

0.4 second (initial condition)

Long

0.8 second

Intelligent/Comf
ort washer

With/without 
Comfort washer 
function

Disable

No function (Initial condition)

Enable

With function

Auto door 
unlock

Adjustment of the 
auto door unlock 
function

Disable

Without function (initial condition)

Always (P pos)

With function: Operates when the shift 
lever or the selector lever is moved to the 
P position.

Always(Lock pos)

With function: Operates when the ignition 
switch is moved to the LOCK (OFF) 
position.

Door unlock 
mode

Adjustment of 
power door locks 
with selective 
unlocking

All Doors Unlock

Without function: The first operation of 
keyless entry system or unlock operation 
by KOS unlocks all doors (initial condition).

Dr Door Unlock

With function: The first operation of 
keyless entry system or unlock operation 
by KOS unlocks the driver's door only, and 
the second unlock operation within 2 
seconds after that unlocks all doors. 

Timer lock timer Timer lock period 

adjustment

30 sec.

30 seconds (initial condition)

60 sec.

60 seconds

120 sec.

120 seconds

180 sec.

180 seconds

Adjustment 
item (M.U.T.-III 
display)

Adjustment item

Adjusting content 
(M.U.T.-III display)

Adjusting content

 

 

 

 

 

 

 