Mercedes-Benz Sprinter / Dodge Sprinter. Manual - part 50

 

  Index      Mercedes     Mercedes-Benz Sprinter / Dodge Sprinter - service repair manual 2006 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  48  49  50  51   ..

 

 

Mercedes-Benz Sprinter / Dodge Sprinter. Manual - part 50

 

 

TEST

ACTION

APPLICABILITY

3

Disconnect the Central Timer Module C1 connector.
Disconnect the Master Door Lock Switch connector.
Measure the resistance between ground and the Driver Door Ajar Indicator Driver
circuit.
Is the resistance below 20000.0 ohms?

All

Yes

→ Repair the Driver Door Ajar Indicator Driver wire for a short to

ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Central Timer Module.

Perform BODY VERIFICATION TEST - VER 1.

197

POWER DOOR LOCKS/RKE

DRIVER DOOR AJAR INDICATOR DRIVER CIRCUIT SHORT TO
GROUND —

Continued

Symptom:

PASSENGER DOOR AJAR INDICATOR DRIVER CIRCUIT SHORT
TO GROUND

When Monitored and Set Condition:

PASSENGER DOOR AJAR INDICATOR DRIVER CIRCUIT SHORT TO GROUND

When Monitored:

Whenever the battery is above 10.0 volts and the module is connected.

Set Condition:

Whenever the CTM senses resistance on the Passenger Door Ajar

Indicator Driver circuit for over 30 seconds, this code will set.

POSSIBLE CAUSES

DTC PRESENT

MASTER DOOR LOCK SWITCH SHORTED

CENTRAL TIMER MODULE SHORTED

PASSENGER DOOR AJAR INDICATOR DRIVER WIRE SHORT TO GROUND

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Cycle the ignition switch from ON to OFF to ON.
With the DRBIII

t, read DTC’s.

Operate the Door Locks several times while observing the DRBIII

t.

Wait 10 seconds.
Does the DRBIII

t display PASSENGER DOOR AJAR INDICATOR CIRCUIT

SHORT TO GROUND?

All

Yes

→ Go To 2

No

→ The conditions that caused this code to set are not present at this

time. Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.

2

Turn the ignition off.
Disconnect the Master Door Lock Switch connector.
Measure the resistance between ground and the Passenger Door Ajar Indicator
Driver circuit..
Is the resistance below 1000.0 ohms?

All

Yes

→ Go To 3

No

→ Replace the Master Door Lock Switch.

Perform BODY VERIFICATION TEST - VER 1.

198

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

3

Disconnect the Central Timer Module C1 connector.
Disconnect the Master Door Lock Switch connector.
Measure the resistance between ground and the Passenger Door Ajar Indicator
Driver circuit.
Is the resistance below 20000.0 ohms?

All

Yes

→ Repair the Passenger Door Ajar Indicator Driver wire for a short

to ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Central Timer Module.

Perform BODY VERIFICATION TEST - VER 1.

199

POWER DOOR LOCKS/RKE

PASSENGER DOOR AJAR INDICATOR DRIVER CIRCUIT SHORT TO
GROUND —

Continued

Symptom:

REPLACE CONTROL MODULE

When Monitored and Set Condition:

REPLACE CONTROL MODULE

When Monitored:

Whenever the battery voltage is above 10.0 volts and the module is

connected.

Set Condition:

The SKREEM has detected an internal failure and must be replaced.

POSSIBLE CAUSES

CTM INTERNAL FAILURE

TEST

ACTION

APPLICABILITY

1

View repair.

All

Repair

Replace the Sentry Key RemotE Entry Module in accordance with
Service Instructions.
Perform BODY VERIFICATION TEST - VER 1.

200

POWER DOOR LOCKS/RKE

 

 

 

 

 

 

 

Content   ..  48  49  50  51   ..