I01387 Condition : Periodically cools and then fails to cool I01388 Condition: Insufficient cooling – AIR CONDITIONING AIR CONDITIONING SYSTEM AC–5 2690 (2) Moisture present in refrigeration system. Symptom seen in refrigeration system Probable cause Diagnosis Remedy During operation, pressure on low pressure side sometimes become a vacuum and sometime normal Moisture entered in refrigeration system freezes at expansion valve orifice and temporarily stops cycle, but normal state is restored after a time when the ice melts Dryer in oversaturated state Moisture in refrigeration system freezes at expansion valve orifice and blocks circulation of refriger- ant (1) Replace dryer (2) Remove moisture in cycle through repeatedly evacuating air (3) Charge proper amount of new refrigerant (3) Insufficient cooling Symptom seen in refrigeration system Probable cause Diagnosis Remedy Pressure low on both low and high pressure sides Bubbles seen in sight glass con- tinuously Insufficient cooling performance Gas leakage at some place in re- frigeration system Insufficient refrigerant in system Refrigerant leaking (1) Check for gas leakage with gas leak detector and repair if neces- sary (2) Charge proper amount of re- frigerant (3) If indicated pressure value is near 0 when connected to gauge, create the vacuum after inspecting and repairing the location of the leak |