TEST
ACTION
APPLICABILITY
8
At this time, the conditions required to set the DTC are not present.
Note: Use the Freeze Frame Data to help you duplicate the conditions that
set the DTC. Pay particular attention to the DTC set conditions, such as,
VSS, MAP, ECT, and Load.
Note: Visually inspect the related wiring harness. Look for any chafed,
pierced, pinched, or partially broken wires.
Note: Visually inspect the related wire harness connectors. Look for broken,
bent, pushed out, or corroded terminals.
Note: Refer to any technical service bulletins that may apply.
Perform a wiggle test of the Evap Purge Solenoid wiring while the circuit is actuated
with the DRBIII
t. Listen for the solenoid to quit actuating. Also watch for the Good
Trip Counter to change to 0.
Were any problems found?
All
Yes
→
Repair wiring harness/connectors as necessary.
Perform POWERTRAIN VERIFICATION TEST VER - 5.
No
→
Test Complete.
173
DRIVEABILITY - GAS
P0441-EVAP PURGE FLOW MONITOR —
Continued