Content .. 1389 1390 1391 1392 ..
NOTE:
When performing voltage or resistance tests, always use a digital multimeter (DMM) accurate to three decimal places and with a current calibration certificate. When testing resistance, always take the resistance of the DMM leads into account.
NOTE:
Check and rectify basic faults before beginning diagnostic routines that involve pinpoint tests.
NOTE:
Inspect connectors for signs of water ingress, and pins for damage and/or corrosion.
NOTE:
If DTCs are recorded and, after performing the pinpoint tests, a fault is not present, an intermittent concern may be the cause. Always check for loose connections and corroded terminals.
DTC
Description
Possible Causes
Action
U2601 D2B Wake up - Short to Ground
•
Voice activated
Refer to electrical circuit diagrams, notes and check voice activated control module (D2B) wake-up line for short to ground
U2609 D2B Wake-up Pulsewidth - Out of spec
•
Voice activated
Refer to electrical circuit diagrams, notes and check voice activated control module (D2B) wake-up line circuit for fault
U2610 D2B Slave ECU - Fails to receive a report position
•
During initialization
Carry out any pinpoint tests associated with this DTC using the manufacturer approved diagnostic system. Refer to electrical circuit diagrams, notes and check (D2B) slave modules and circuit for fault, replace as required, refer to the new module installation note at the top of the DTC Index
|