Content .. 1316 1317 1318 1319 ..
-> No GO to Pinpoint Test G240121t101.
G240121t94 : CHECK FOR SHORT TO GROUND AT VR02, PIN 16 1. Disconnect intermediate connector, VR02. 2. Measure the resistance between VR02, pin 16 (RG) and GROUND. •
Is the resistance less than 10,000 ohms? -> Yes INSTALL a new harness between VR01 and VR02. TEST the system for normal operation.
-> No GO to Pinpoint Test G240121t95.
G240121t98 : CHECK THE CIRCUIT BETWEEN VR01 AND VR02 FOR 1. Measure the resistance between VR01, pin 16 (RG) and VR02, pin 16 (RG). •
Is the resistance greater than 5 ohms? -> Yes INSTALL a new harness between VR01 and VR02. TEST the system for normal operation.
-> No GO to Pinpoint Test G240121t99.
G240121t95 : CHECK FOR SHORT TO GROUND AT TL91, PIN 16 1. Disconnect intermediate connector, TL91. 2. Measure the resistance between TL91, pin 16 (RG) and GROUND. •
Is the resistance less than 10,000 ohms? -> Yes INSTALL a new harness between VR02 and TL91. TEST the system for normal operation.
-> No GO to Pinpoint Test G240121t96.
|