1-82  HEATER AND AIR CONDITIONING 

 

  

 

RTW710SH000801 

 

Fan switch and A/C switch 

Check for continuity between fan switch and A/C switch side 
connector terminals. 
(A/C (4JA1-T, 4JJ1-TC Standard Output, 4JJ1-TC High 
Output, 4JK1-TC High Output)) 
 

 

B-13 B-57 

 

Terminal

No.

SW. 
position

 

1

2

3

3

1

5

6

OFF 

    

 

 

 

 

 

 

 

 

 

 

 

 

(FAN SW.)

 

 

 

 

OFF 

    

(A/C SW.)

ON 

 

 

 

 

 

  

 

RUW710SH000501 

 

(A/C (4JH1-TC, C24SE)). 
 

 

 

 

B-13 B-57 

 

Terminal

No.

SW. 
position

 

1

2

6

1

5

6

OFF 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(FAN SW.)

 

 

 

 

 

 

 

 

 

OFF 

 

 

 

 

 

 

 

 

 

(A/C SW.)

ON 

 

 

 

 

 

 

 

 

 

D08R300070 

 

(Cooler) 
 

 

 

 

B-13 B-57 

 

Terminal

No.

SW. 
position

 

1

2

3

4 5 6 2

3

10

11

OFF 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(FAN SW.)

 

 

 

 

 

 

 

 

 

 

OFF 

 

 

 

 

 

 

 

 

 

 

(A/C SW.)

ON 

 

 

 

 

 

 

 

 

 

 

HEATER AND AIR CONDITIONING  1-83 

 

  

 

RTW410SH000201 

 

Electronic thermostat 

Check for continuity between electronic thermostat side 
connector terminals. 
(A/C) 
 

 

 

(Cooler) 

1-84  HEATER AND AIR CONDITIONING 

 

  

 

RTW4A0SH000201 

 

Triple Pressure switch 

Disconnect pressure switch connector and check for continuity 
between pressure switch side connector terminal. 
 
 

825r300045 

 

 

Heater and thermo switch relay. 

Check for continuity between the relay terminals. 

 1   -   5    ⋅⋅⋅⋅⋅  No continuity 

(When battery voltage is applied between   2   -   4   ) 

1   -   5    

⋅⋅⋅⋅⋅  Continuity 

825r300023 

 

 

Check for continuity between the relay terminals. 

 1   -   2    ⋅⋅⋅⋅⋅  No continuity 

(When battery voltage is applied between   3   -   4   ) 

1   -   2    

⋅⋅⋅⋅⋅  Continuity 

 
 
 

HEATER AND AIR CONDITIONING  1-85 

TROUBLESHOOTING 

FAN CONTROL KNOB (FAN SWITCH) 

Current flows to the blower motor through the Heater & A/C relay (X-11) to activate the rotation of the blower motor 
by turning “ON” the fan control knob (fan switch). Blower motor speed is controlled in stages by the resistor, by 
operating the switch from “LOW” to “HIGH.” 
 

 

 

 

RTW710LF004201 

 

 

 

 

 

 

 

Content   ..  27  28  29  30   ..