DTC P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-441 C D E F G H I J K L M A EC DTC Confirmation Procedure NBS000TB NOTE: WITH CONSULT-II 1. Turn ignition switch OFF and wait at least 10 seconds. 2. Turn ignition switch ON and select “DATA MONITOR” mode with 3. Start engine and wait at least 40 seconds. NOTE: EC-441, "Diagnostic Procedure" . WITH GST Follow the procedure “WITH CONSULT-II” above. Diagnostic Procedure NBS000TC 1. CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF. 2. Loosen and retighten two ground screws on the body. Refer to . OK or NG OK >> GO TO 2. NG >> Repair or replace ground connections. SEF194Y PBIB2192E |